SMAX MODBUS®
the page of the website dedicated to the device. The program is designed to be
installed simply by copying the executable file to the desired location and
no
installation process
is required. To launch the program just double-click the file
icon. To close the program press the
CLOSE
button at the top right of the
window.
NOTE
Before starting the program and establishing a communication with the device,
it is necessary to connect it to the personal computer. The interface of the SMAX
encoder is a serial RS-485 type, the standard of the serial port in the personal
computer (when the port is available) is the RS-232 type. Therefore you must
install an RS-232 to RS-485 converter, easily available in the market. Should the
personal computer not be equipped with a serial port (RS-232 or RS-485), you
must install a USB to RS-485 converter, easily available in the market too. For
complete information on the connection scheme and the cable pinout refer to
the instruction sheet provided with the converter.
On the ENCODER side the cable must be connected as described in the
“Electrical connections” section on page 19. Always be sure that RX wire in the
MODBUS ENCODER is connected up to TX wire in the PC and RX wire in the PC
is connected up to TX wire in the MODBUS ENCODER.
MAN SMAX MB E 1.2
Quick reference
26 of 84