SMAX MODBUS®
Min. bend radius
: Ø x 7.5
Work temperature
: -40°C +90°C (-40°F +194°F) – dynamic installation
-50°C +90°C (-58°F +194°F) – fixed installation
Conductor resistance :
90
/km /
148
/km
4.1.2 M12 8-pin connector
Male, frontal side
A coding
4.2 Ground connection
To minimize noise connect properly the shield and/or the connector housing
and/or the frame to ground. Connect properly the cable shield to ground on
user's side. Lika's EC- pre-assembled cables are fitted with shield connection to
the connector ring nut in order to allow grounding through the body of the
device. Lika's E- connectors have a plastic gland, thus grounding is not possible.
If metal connectors are used, connect the cable shield properly as recommended
by the manufacturer. Anyway make sure that ground is not affected by noise. It
is recommended to provide the ground connection as close as possible to the
device.
MAN SMAX MB E 1.2
Electrical connections
20 of 84