RD4 CANopen®
Example 1
Default values:
3120-00 Distance per revolution
= 1024 steps per revolution
= 1600 pulses per second for RD4-...T32-... model (1600*1024/1024 = 1600)
= 1066 pulses per second for RD4-...T48-... model (1066*1024/1024 = 1066)
Positive delta
Negative
delta
max. values = 523263 = (1024 steps per revolution x 511 revolutions) - 1
when
= 0 + 523263 = + 523263 pulses (forward travel)
= 0 - 523263 = - 523263 pulses (backward travel)
= 0, the working stroke of the axis will span
the maximum positive and negative limits range, that is
= - 523263.
MAN RD4 CB E 1.5
Functions
30 of 72
Содержание RD4