RD4 CANopen®
8.2 Warning messages
For the complete list and the meaning of the warning messages please refer to
“SDO abort codes” section in “CiA Draft Standard 301” document available at
www.can-cia.org.
8.3 Emergency messages
Emergency (EMCY) objects are issued by the device when an internal error
occurs.
Structure of EMCY object:
IDENTIFIER
CAN Data Byte
COB-ID(hex)
0
1
2
3…7
See object 1014h
Error code
Errors sub-register Specific codes
LSB
MSB
01
00…00
Emergency codes available:
0000h
No active errors
1000h
Generic error
2220h
Power surge
3110h
Overvoltage
3120h
Undervoltage
4310h
Overtemperature
5530h
Flash memory
8130h
Life Guard
8611h
Following error
MAN RD4 CB E 1.5
Programming parameters
67 of 72
Содержание RD4