LD220
6.15 Linearization menu
The linearisation function is configured in this menu. This menu is displayed
only if the
General
menu (see on page
39) is set to either “1 – 1 QUADRANT” or “2 – 4 QUADRANT”; if 0 – OFF option is
set the
Linearization
menu does not appear.
For a complete description of the linearisation function and some examples
refer to the “6.15.1 Description of the linearisation function” section below.
Source
This parameter sets the reference source which has to be used for linearization.
0 POSITION
Result of the position measurement
1 SPEED
Result of the speed measurement
P1(X)
…
P24(X)
X-coordinate of the linearisation point.
This value represents the display value the unit shows on the display without
linearisation.
-99999999
Smallest X-coordinate
+00000000
Default value
+99999999
Largest X-coordinate
P1(Y)
…
P24(Y)
Y-coordinate of the linearisation point.
This is the display value the unit will show on the display after linearisation.
EXAMPLE
P2(X)
parameter value will be replaced by
P2(Y)
parameter value.
-99999999
Smallest Y-coordinate
+00000000
Default value
+99999999
Largest Y-coordinate
MAN LD220 E 1.4.odt
6 – Menus and parameters
83 of 100
Содержание Posicontrol LD220 Series
Страница 99: ...This page intentionally left blank...