LD220
Serial init
This parameter allows to set the baud rate for the transmission of the
initialization values to the OS software tool. If you set transmission values
higher than 9600 baud, the duration of the initialization procedure will be
shortened.
0 NO
The initialization values will be transmitted at 9600
baud. After initialization the unit will operate
according to the user settings again.
1 YES
The initialization values will be transmitted
according to the user defined baud rate (
parameter). After initialization the unit
will go on operating according to the user settings
again.
Serial protocol
It sets the sequence of characters to be sent when using the serial output for
cyclic data transmission under time control (see the
parameter).
If you set the option “1“ the unit address is removed from the string, this results
in a slightly faster transmission cycle.
The transmission string will be as follows:
Option 0
UN
UN + / -
X
X
X
X
X
X
X
LF
CR
Option 1
+ / -
X
X
X
X
X
X
X
LF
CR
Where:
UN UN
= serial address, e.g. “1 1”. See the
the previous page (option
0
only)
+ / -
= plus / minus signs, i.e. positive / negative sign of transmitted
value
X X X X X X X X = data to be transmitted according to the setting in the
parameter
LF
= line feed character
CR
= carriage return character
0
Transmission string with serial address
1
Transmission string without serial address
MAN LD220 E 1.4.odt
6 – Menus and parameters
72 of 100