LD220
Start up delay 1 (s)
Start up delay setting for the switching condition of
. It is the
delay before starting the monitoring function.
This adjustment only applies to the switching conditions
1 - |RESULT|<=|
PRES|
and
4 - RESULT<=PRES
parameter on page 61). When
the display value is 0, the start up delay is set to this parameter. The timer starts
when the display value is not equal to 0. The monitoring function remains
deactivated until the set time has elapsed.
00.000
No start up delay setting
…
60.000
Start up delay setting expressed in seconds
NOTE
respectively) have an automatic start up delay setting.
Event color 1
Event-depending change of colour of the display for the switching condition of
and
are allowed to overwrite this change of colour.
0 NO CHANGE
No change of colour
1 CHANGE TO RED
Colour of display changes to red
2
CHANGE TO
GREEN
Colour of display changes to green
3
CHANGE TO
YELLOW
Colour of display changes to yellow
MAN LD220 E 1.4.odt
6 – Menus and parameters
64 of 100