EM58 – HS58 - HM58 MODBUS TCP/IP
Byte 0
Scaling function
bit 0
It shows whether the scaling function (see the bit 0
registers) is currently disabled or enabled.
If the value is “=0” the scaling function is disabled (i.e.
the system uses the physical values -
- to calculate the position information); if
the value is “=1” the scaling function is enabled (i.e.
the system uses the custom resolution values –
Counts per revolution [101-102]
- to calculate the position
information). To disable / enable the scaling function
you must set the bit 0
Operating parameters [109-110]
For any further information on setting and using the
scaling function refer to the
parameter on page 58.
Code sequence
bit 1
It shows whether the code sequence (see the bit 1
registers) is currently set to clockwise (CW) or
counter-clockwise (CCW). If the bit is “=0” the output
encoder position value has been set to increase
(count up information) when the encoder shaft
rotates clockwise; if the bit is “=1” the output encoder
position value has been set to increase when the
encoder shaft rotates counter-clockwise. To set the
code sequence to either CW or CCW you must set the
bit 1
registers to 0 / 1. For any further
information on setting and using the counting
direction function refer to the
parameter on page 59.
bits 2 … 7
Not used.
Byte 1
Alarm
bit 8
If the value is “=1” an alarm has occurred, see details
in the
bits 9 … 15
Not used.
MAN EM58_HS58_HM58 MT E 1.1.odt
Programming parameters
69 of 104