EM58 – HS58 - HM58 MODBUS TCP/IP
Status word [99-100]
input registers are also available as holding registers at
the address 98-99 and accessible by using the
function code. For any information refer to page 68.
Counts per revolution [101-102]
[100-101, Unsigned32, rw]
WARNING
These registers are active only if the bit 0
registers is set to “=1”; otherwise they are ignored and
the system uses the physical values (see the
Singleturn resolution [113-114]
Number of revolutions [115-116]
registers) to calculate the position
information.
These registers set the custom number of distinguishable steps per revolution
that are output for the absolute singleturn position value.
You are allowed to set whatever integer value less than or equal to the
maximum number of physical steps per revolution
registers).
If you enter an out-of-range value (i.e. greater than the maximum number of
physical steps per revolution), the value is not accepted.
To avoid counting errors, please check that:
Singleturn resolution [113-114]
= integer value.
Counts per revolution [101-102]
Default = 8192 (min. = 1, max. = 8192)
for EM58 series
262144 (min. = 1, max. = 262144)
for HS58 series
65536 (min. = 1, max. = 65536)
for HM58 series
WARNING
To avoid counting errors please always make sure that the following condition is
met:
=
a power of 2.
Counts per revolution [101-102]