EM58 – HS58 - HM58 MODBUS TCP/IP
than or equal to the “Total hardware resolution” - 1, i.e. (
Number of revolutions [115-116]
) - 1.
- 1.
WARNING
preset operation if necessary (the bit 11
registers = 1) every time you set a new
or change the scaled values (
and / or
registers).
Speed format [107-108]
[106-107, Unsigned16, rw]
These registers define the engineering unit for the velocity value (see the
0 = steps/s:
number of steps per second;
1 = rpm:
revolutions per minute.
Default = 0 (min. = 0, max. = 1)
Operating parameters [109-110]
[108-109, Unsigned16, rw]
Bit
Function
bit = 0
bit = 1
0
disabled
enabled
1
CW (clockwise)
CCW (counter clockwise)
2 … 31
not used
Default values are highlighted in bold
Default = 0000 0000 hex (min. = 0000 0000 hex, max. = 0000 0003 hex)
Byte 0
Scaling function
bit 0
If this function is disabled (the bit 0
the devices uses the physical resolution to arrange the
absolute position value (see the
Number of revolutions [115-116]
registers); if this function is enabled (the bit 0
= 1), the device uses the custom resolution set
Counts per revolution [101-102]