EM58 – HS58 - HM58 MODBUS TCP/IP
Furthermore, after having set a new value next to the
registers, make sure that also the following condition is met:
≤
Number of physical
revolutions (see
Counts per revolution [101-102]
Let's suppose that the HM5816/16384MT encoder is programmed as follows:
Counts per revolution [101-102]
: 8192
= 33,554,432 = 8192 (cpr) * 4096 (rev.)
Let's set a new singleturn resolution, for instance:
= 360.
we will get the following result:
Number of revolutions
=
33,554,432 (
= 93,206.755...
360 (
Counts per revolution [101-102]
As you can see, the encoder is required to carry out more than 93,000
revolutions, this cannot be as the hardware number of revolutions is, as stated,
16,384 (see the
Singleturn resolution [113-114]
happens, the value is not accepted.
WARNING
If you have set the preset, every time you change the value next to the
registers, then you must check the value in the
registers; if necessary you are required to set a new
preset and perform the preset operation (bit 11
registers = 1).
Total Resolution [103-104]
[102-103, Unsigned32, rw]
WARNING
These registers are active only if the bit 0
registers is set to “=1”; otherwise they are ignored and
the system uses the physical values (see the
Singleturn resolution [113-114]
Number of revolutions [115-116]
registers) to calculate the position
information.