EM58 – HS58 - HM58 MODBUS TCP/IP
must be switched back to logic level low (“0”) to make the
function available again. The complete list of machine data
and relevant default parameters preset by Lika Electronic
engineers is available on page 100.
WARNING
The execution of this command causes all parameters which
have been set previously to be overwritten!
Perform counting preset
bit 11
This command is used to activate a preset value in the
encoder. As soon as the command is sent, the position value
which is transmitted for the current encoder position is the
one set next to the
all the previous and following positions will get a value
according to it. The operation is performed at each rising
edge of the bit, i.e. each time this bit is switched from logic
level low (“0”) to logic level high (“1”). Then the bit must be
switched back to logic level low (“0”) to make the function
available again. When the command is sent, the current
encoder position is saved temporarily in the
registers. For any further information on the
preset function and the meaning and use of the related
registers and commands
page 56.
WARNING
To save permanently the current encoder position in the
command. Should the power supply be turned
has not been saved will be lost!
bits 12 … 15
Not used.
Bytes 2 and 3
Not used.
NOTE
Always save the new values after setting in order to store them in the non-
volatile memory permanently. Use the
60.
Should the power supply be turned off all data that has not been saved
previously will be lost!
MAN EM58_HS58_HM58 MT E 1.1.odt
Programming parameters
61 of 104