EM58 – HS58 - HM58 MODBUS TCP/IP
OFF
The encoder power supply is switched OFF.
ON
The encoder power supply is switched ON.
LED
Description
MS Module
Status LED
(
green
/
red
)
It shows the state of the MODBUS TCP/IP device.
OFF
The device power supply is switched OFF.
ON
green
The device is in normal operational state.
ON
red
Major fault, FATAL ERROR.
FLASHING
red
Minor fault.
LED
Description
L/A Link/Activity
LED for port 2
P2 (
green
)
It shows the state and the activity of the physical link (port
2 P2).
BLINKING
Activity on port 2 P2.
ON
Port 2 P2 link active, no activity.
NOTE
If both the NS Network Status LED and the MS Module Status LED are red, a
fatal error has occurred.
NOTE
During startup, the device carries out a hardware test to check the LEDs
operation.
Both NS Network Status and MS Module Status LEDs light up.
4.8 DIP A: Resetting the network configuration parameters to the factory
values
WARNING
To access the DIP A DIP switch meant to reset the network configuration
parameters to the factory values (default values) you must remove the
MAN EM58_HS58_HM58 MT E 1.1.odt
Electrical connections
30 of 104
Содержание EMC58 MT
Страница 101: ...This page intentionally left blank ...
Страница 102: ...This page intentionally left blank ...
Страница 103: ...This page intentionally left blank ...