Lika AM 58 P Series Скачать руководство пользователя страница 7

 

AMx58x P

 

MAN AMx58x P I_E 1.5.doc 

Pag. 7/16 

www.lika.it  

 

 

www.lika.biz  

7 ! Ingombri meccanici 

7.1 AM58 P 

 

7.2 AM58S P 

 

 
 

7.3 AMC58 P 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание AM 58 P Series

Страница 1: ...ti dall inverter Installare degli appositi filtri EMC reperibili in commercio all ingresso dell alimentazione dell encoder generalmente sufficiente un filtro a T del tipo LAC oppure in alternativa un...

Страница 2: ...iori contattare il nostro personale tecnico E41MLS Connettore standard 41 poli Pin Funzione Pin Funzione A Out 1 LSB Y Out 22 B Out 2 Z Out 23 C Out 3 a Out 24 D Out 4 b Out 25 MSB E Out 5 c Parity F...

Страница 3: ...rfaccia seriale Baud rate 9600 baud Data 8 bit stop 1 bit Controllo di flusso Xon Xoff Parity Consente di verificare il corretto funzionamento delle uscite o l integrit delle connessioni L uscita del...

Страница 4: ...sto txt ed inviato all encoder direttamente dal programma di Terminal Es Hyperterminal menu Trasferisci A Invia File di testo 6 3 Comandi di comunicazione DEV 1 127 DEVice Assegnazione dell indirizzo...

Страница 5: ...completare correttamente 6 x 682 4092 Al raggiungimento del 4096 giro fisico l encoder per le sua propriet di dispositivo assoluto si azzera pertanto l errore di riporto di 4096A4092 4 giri Esempio 2...

Страница 6: ...ata tramite comando PRST1 Es PRST1 100 impostare la quota di stop desiderata tramite comando PRST2 Es PRST2 1100 Preset1 1 2 Preset2 Start Stop 1 inizio teachAin 2 fine teachAin portare l encoder in p...

Страница 7: ...AMx58x P MAN AMx58x P I_E 1 5 doc Pag 7 16 www lika it www lika biz 7 Ingombri meccanici 7 1 AM58 P 7 2 AM58S P 7 3 AMC58 P...

Страница 8: ...P I_E 1 5 doc Pag 8 16 www lika it www lika biz Lika Electronic Via S Lorenzo 25 36010 Carr VI A Italy Tel 39 0445 806600 Fax 39 0445 806699 Italy eMail info lika it A www lika it World eMail info lik...

Страница 9: ...sales staff 2 Identification The device can be identified by the label s data ordering code serial number This information is listed in the delivery document The technical features of the product can...

Страница 10: ...ND EML121 12 pin connector SSI output Pin Function Pin Function 1 clock A 7 Zero setting 2 clock 8 Complementary 3 data 9 Preset 1 4 data A 10 Preset 2 5 TxD 11 10Vdc 30Vdc 6 RxD 12 0Vdc GND 40 wires...

Страница 11: ...the transmission of output information from the encoder to be blocked In this it is possible to work with several encoder in parallel multiplexing using a single control unit acquiring the informatio...

Страница 12: ...oder accepts address zero 0 which allows to communicate even if the real address is unknown RST ReSeT Resets all encoder parameters to default condition factory setting Syntax RST 6 4 Encoder output s...

Страница 13: ...be disabled until a new EXTD command is send Syntax EXTD EVEN Parity bit EVEN Sets parity bit even Parity bit will be logic level low when the sum of output bits with logic level high is even Syntax...

Страница 14: ...osition 1099 deactivate Preset2 input low to terminate teachAin procedure as result of the above example the measurement length is 1000 steps from position 100 to 1099 ATTENTION the desired resolution...

Страница 15: ...AMx58x P MAN AMx58x P I_E 1 5 doc Pag 15 16 www lika it www lika biz 7 Dimensional drawing 7 1 AM58 P 7 2 AM58S P 7 3 AMC58 P...

Страница 16: ...I_E 1 5 doc Pag 16 16 www lika it www lika biz Lika Electronic Via S Lorenzo 25 36010 Carr VI A Italy Tel 39 0445 806600 Fax 39 0445 806699 Italy eMail info lika it A www lika it World eMail info lik...