Page 74 / 129
Section
6
.
Web
control
– Using built-in website
6.4.1. Change emulated EDID at one or all inputs
All EDIDs are enumerated in the
EDID list
window.
Step 1.
Select the desired EDID from this list with a left mouse click, a popup menu
appears.
Step 2.
Click the “Switch this EDID to” item. A popup menu appears with an input name list.
Step 3.
Click on the desired input, or on the ALL text. Now the EDID has been changed on
selected input as the message box shows on the left corner.
Figure 6-5. Static EDID routing
Info:
Switching an EDID to ALL inputs may take several seconds.
Switching an EDID from Monitor 1 .. Monitor 4 (called as Last Attached Monitors EDIDs) to
an input results dynamic EDID routing. This means that the emulated EDID changes
automatically, if a new monitor is attached to the output, by simply copying the data from
the monitor.
Figure 6-6. Dynamic EDID routing
6.4.2. Learn EDID from attached display device
The matrix switcher can learn the EDID from a connected display device and store it in one
of the user programmable memory locations. All the monitor's EDIDs are listed in the
EDID