Modular Extender family 

Quick Start Guide 

 

Section 

5

. Web control 

– Using the Built-in website 

Page 11 / 15 

5.4.2.2.  Audio crosspoint 

In  the  main  menu  left  click  on  the 

Crosspoint

 

label  then  left  click  on 

Audio

  label  the 

audio crosspoint appears. The inputs  are at the top row and the outputs  are at the right 
column. The number of the inputs and the outputs depends on the number, the direction 
and the mode settings of the audio modules.  

OPTx extenders support two audio groups the 

Main  audio  group

  and  the 

S/Pdif  audio 

group

.  These  groups  are  independent  from 

each  other.  In  this  case  there  are  forbidden 
crosspoint connections. 

The  link  can  support  four  audio  layers.  The 

Embedded  audio

  (from  Tx  to  Rx)  and  the 

Return  AUX 

(from  Rx  to  Tx)  belongs  to  the 

Main  audio  group.  The 

Forward  Audio

  (from  Tx  to  Rx)  and 

Return  Audio

  (from  Rx  to 

Tx) belongs to the S/PDIF audio group. 

  

At  the  transmitter 
side the 

Embedded 

audio 

and 

the

 

Forward 

Audio 

appears 

as 

an 

output,  the 

Return 

Audio

 

and 

the 

Return 

AUX

 

appears 

as 

an 

input. 

At 

the 

receiver  side  the 
direction 

is 

the 

opposite. 

 

 

 

 

 

The  input  and  output  settings  can  be  accessed  through  module  and  port  properties. 
Every port is represented with a connector icon, while the modules are represented with a 
colored bar. Some modules have multiple ports so the module settings may affect which 
ports can be used. Ports settings can be accessed through the 

Port property  icon

. The 

module settings can be accessed through the 

Module property

 bar. 

 

 

Содержание Modex-Rx

Страница 1: ...MODEX TX MODEX RX Modular Extender family MODEX Quick Start Guide ...

Страница 2: ...GENERAL DESCRIPTION 5 2 1 FRONT VIEW 5 2 2 REAR VIEW 6 3 INSTALLATION 6 4 FRONT PANEL OPERATIONS 7 5 WEB CONTROL USING THE BUILT IN WEBSITE 7 5 1 NETWORK STRUCTURE 7 5 2 IP SETTINGS 8 5 3 ESTABLISHING THE CONNECTION 8 5 4 BUILT IN WEB 9 5 4 1 Main menu 9 5 4 2 Crosspoint menu 9 5 4 3 EDID menu 14 5 4 1 Settings 15 6 WARRANTY 15 7 DOCUMENT REVISION HISTORY 16 ...

Страница 3: ...ting the AV and broadcast industry s formats It is capable of extending digital and analog audio and video USB KVM Ethernet and control signals like RS 232 RS 422 IR etc 1 1 Box contents Quick Start Guide this document MODEX Transmitter or Receiver unit IEC Power cable UTP LAN cable Four rubber foot Infrared transmitter and receiver pair 5 pole male phoenix connector 1 2 Typical applications ...

Страница 4: ...ly of each other The MODEX is fully compatible with the 25G hybrid architecture 2 1 Front view USB KVM1 1x USB B connector is on the TX side and 2x USB A connectors are on the RX side USB KVM USB connection to HOST Computer on the TX unit and for two devices e g Keyboard on the RX unit Ethernet Ethernet connection for control and transfer Link status LEDs Audio LED lights green when the audio tran...

Страница 5: ...ver Both devices can be accessed and controlled through either Ethernet port Step 5 Optionally for Ethernet extension connect some Ethernet devices e g switch laptop computer etc to the transmitter and to the receiver All connected devices will work as if they are connected to the same network Step 6 Optionally for RS 232 extension Connect a controller unit e g Touch panel to the RS 232 on TX with...

Страница 6: ...Manufacturer Product Serial VID PID Host info Port2 Manufacturer Product Serial VID PID Host info EDID Presets Load preset Save preset A Modex might have more than one video or interface module of the same kind The appropriate number of branches of the tree appears in this case 5 Web control Using the Built in website Modex transceivers have several configuration options More settings are availabl...

Страница 7: ... 0 1 HTTP port 80 WEB socket 81 Receiver IP address 192 168 0 102 port number 6107 subnet mask 255 255 255 0 gateway 192 168 0 1 HTTP port 80 WEB socket 81 Set a user defined static IP address The IP address Subnet mask Static gateway and the Port number can be set by a user defined value on the front panel LCD menu Settings Network Settings or remotely through the built in website Settings Networ...

Страница 8: ...menu to obtain layers of configuration panel supported by the selected Modex extender pair Note USB KVM has no crosspoint configuration panel Note If a layer is not supported by the selected MODEX then there is no label for its properties 5 4 2 1 Video crosspoint In the main menu left click on the Crosspoint label then left click on Video label the video crosspoint appears The inputs are at the to...

Страница 9: ...ts but only one of these inputs or outputs can be used in the video crosspoint This is because only one video stream transmission is permitted between the core module and the video module After setting the mode of the video interface module the supported input or output port of the selected mode appears in the video crosspoint and the port property becomes available Port property Left click on the...

Страница 10: ...ink can support four audio layers The Embedded audio from Tx to Rx and the Return AUX from Rx to Tx belongs to the Main audio group The Forward Audio from Tx to Rx and Return Audio from Rx to Tx belongs to the S PDIF audio group At the transmitter side the Embedded audio and the Forward Audio appears as an output the Return Audio and the Return AUX appears as an input At the receiver side the dire...

Страница 11: ... Main or S PDIF using the mode function After setting the mode of the audio interface module the supported input and or output port of the selected mode appears in the audio crosspoint and the port property window becomes available The Mode function list is continuously expanding with new features and audio functions and it is possible to implement future costumer needs Port property Left click on...

Страница 12: ...mation about the selected interface module that contains the infra port Port property Left click on the Port property icon a property window opens In the settings list the carrier frequency at the output ports can be set 5 4 2 4 Serial crosspoint In the main menu left click on the Crosspoint label then left click on Serial label the serial crosspoint appears The inputs are at the top row and the o...

Страница 13: ...The Dynamic EDID contains the EDID list of the sinks have been connected to the extenders User EDID contains the user defined EDID list To manipulate EDIDs they can be copied from the left window to the right window Emulate an EDID Step 1 Select if you want to emulate an EDID from the Factory Dynamic or User EDID memories in the left window Step 2 Browse for the desired EDID in the left window and...

Страница 14: ...menu contains general information and status about the core module Network Network parameters can be set See 5 1 section of this document Status Software supply temperature and module information can be read out System log Operational information warnings errors can be read out Backup The extenders support eight preset settings In this menu these presets can be saved and presets can be load USB KV...

Страница 15: ...story 7 Document revision history Document Release Date Changes Editor Rev 1 1 15 05 2013 Front panel operation has changed section 4 Audio group concept has changed section 5 4 2 2 Peter Petrik Rev 1 0 25 03 2013 initial version Peter Petrik ...

Отзывы: