7. LW3 Programmer's Reference
HDMI-TPS-RX220AK – User's Manual
72
Applied firmware package: v1.4.0 | LDC software: v2.4.0b3
7.4.
System Commands
7.4.1. Query the Product Name
The name of the product is a read-only parameter and cannot be modified.
Command and Response
#producttype
ç
GET·/.ProductName
æ
pr·/.ProductName=
<Product_name>
Example
ç
GET /.ProductName
æ
pr /.ProductName=HDMI-TPS-RX220AK
7.4.2.
Set the Device Label
ATTENTION!
The device label can be changed to a custom text in the
writable parameter is not the same as the ProductName parameter.
Command and Response
#devicelabel #label
ç
SET·/MANAGEMENT/UID/DeviceLabel=
<Custom_name>
æ
pw·/MANAGEMENT/UID/DeviceLabel=
<Custom_name>
The Device Label can be 39 character length and ASCII characters are allowed. Longer names are truncated.
Example
ç
SET /MANAGEMENT/UID.DeviceLabel=RX220_Conference1
æ
pw /MANAGEMENT/UID.DeviceLabel=RX220_Conference1
7.4.3. Query the Serial Number
Command and Response
#serialnumber
ç
GET·/.SerialNumber
æ
pr·/.SerialNumber=
<serial_number>
Example
ç
GET /.SerialNumber
æ
pr /.SerialNumber=87654321
7.4.4. Query the Firmware Version
Command and Response
#firmwareversion
ç
GET·/SYS/MB.FirmwareVersion
æ
pr·/SYS/MB.FirmwareVersion=
<firmware_version>
Example
ç
GET /SYS/MB.FirmwareVersion
æ
pr /SYS/MB.FirmwareVersion=1.4.0b12 r74
7.4.5.
Identify the Device
Calling the method results the blinking of the status LEDs for 10 seconds. The feature helps to identify the
device itself in the rack shelf.
Command and Response
#identifyme
ç
CALL·/MANAGEMENT/UI:identifyMe()
æ
mO·/MANAGEMENT/UI:identifyMe=
Example
ç
CALL /MANAGEMENT/UI:identifyMe()
æ
mO /MANAGEMENT/UI:identifyMe
7.4.6.
Dark Mode
This command turns LEDs off the on the transmitter.
Command and Response
#darkmode
ç
SET·/MANAGEMENT/UI/DARKMODE.DarkModeEnable=
<logical_value>
æ
pw·/MANAGEMENT/UI/DARKMODE.DarkModeEnable=
<logical_value>
Parameters
Identifier
Parameter description
Value
Explanation
<logical_value>
Status of the dark mode
true
Dark mode is enabled.
false
Dark mode is disabled.
Example
ç
SET /MANAGEMENT/UI/DARKMODE.DarkModeEnable=true
æ
pw /MANAGEMENT/UI/DARKMODE.DarkModeEnable=true