6. LW2 Programmer's Reference
HDMI-TPS-RX220AK – User's Manual
65
Applied firmware package: v1.4.0 | LDC software: v2.4.0b3
6.6.4.
Local RS-232 Control Protocol Port Setting
The control protocol of local RS -232 port can be set as follows.
Command and Response
ȩ
{RS232_LOCAL_PROT=
<protocol>
}
Ȩ
(RS232_LOCAL_PROT=
<protocol>
)CrLf
Parameters
Identifier
Parameter description
Value
Parameter value
<protocol>
RS-232 control protocol
LW2
LW2 control protocol
LW3
LW3 control protocol
Example
ȩ
{rs232_local_prot=lw2}
Ȩ
(RS232_LOCAL_PROT=LW2)
INFO:
The current local RS-232 parameters can be queried by the {RS232_LOCAL_PROT=?} command.
6.6.5.
Link RS-232 Control Protocol Port Setting
The control protocol of link RS -232 (TPS) port can be set as follows.
Command and Response
ȩ
{RS232_LINK_PROT=
<protocol>
}
Ȩ
(RS232_LINK_PROT=
<protocol>
)CrLf
Parameters
Identifier
Parameter description
Value
Parameter value
<protocol>
RS-232 control protocol
LW2
LW2 control protocol
LW3
LW3 control protocol
Example
ȩ
{rs232_link_prot=lw2}
Ȩ
(RS232_LINK_PROT=LW2)
INFO:
The current local RS-232 parameters can be queried by the {RS232_LINK_PROT=?} command.