10. Appendix
HDMI-TPS-RX220AK – User's Manual
113
Applied firmware package: v1.4.0 | LDC software: v2.4.0b3
10.4.
Factory Default Settings
Parameter
Setting/Value
Video port settings
TPS mode
Auto
Signal type (HDMI/DVI)
Auto
HDCP
Enabled
Emulated EDID on input ports
F47 (1920x1080p60Hz, 2chLPCM)
Test pattern mode
Disabled
Test pattern clock source
480p
Test pattern
Bar
Output HDMI mode
Auto
Output HDCP mode
Auto
Power 5V mode
Always on
Analog audio port settings
Volume
0.00 dB (100%)
Balance
0 (center)
Network settings
IP address
192.168.0.100
Subnet mask
255.255.255.0
Static gateway
192.168.0.1
DHCP
Disabled
Port numbers (LW2 / LW3 / HTTP)
10001 / 6107 / 80
TPS Ethernet status
Enabled
RS-232 settings
Control protocol
LW2
Baud rate
57600
Databits
8
Parity
No
Stopbits
1
Operation mode (Link and Local)
Pass-through
Command injection port nr. (Local / TPS) 8001 / 8002
IR port settings
Command injection status
Enabled
Comm. inj. input port nr. (Local / TPS)
9001 / 9002
Comm. inj. output port nr. (Local / TPS)
9003 / 9004
10.5.
Maximum Extension Distances
Resolution
Pixel clock
rate
Cable lengths ( Auto / Longreach TPS mode)
CAT5e AWG24
CAT7 AWG26**
CAT7 AWG23
1024x768@60Hz
65 MHz
100 m / 130 m*
90 m / 120 m*
120 m / 170 m*
1280x720p@60Hz
73.8 MHz
100 m / 130 m*
90 m / 120 m*
120 m / 170 m*
1920x1080p@60Hz / 24bpp
148.5 MHz
100 m / 130 m*
90 m / 120 m*
120 m / 170 m*
1920x1200@60Hz
152.9 MHz
100 m / NA
90 m / NA
120 m / NA
1600x1200@60Hz
162 MHz
100 m / NA
90 m / NA
120 m / NA
1920x1080@60Hz / 36bpp
223.6 MHz
70 m / NA
70 m / NA
100 m / NA
3840x2160@30Hz UHD
297 MHz
70 m / NA
70 m / NA
100 m / NA
4096x2160@30Hz 4K
297 MHz
70 m / NA
70 m / NA
100 m / NA
* With Long reach operation mode which supports pixel clock frequencies up to 148.5 MHz.
** When remote powering is used with AWG26 cables, distances are 20% shorter.
10.6.
Cable Wiring Guide
Cable Wiring Guide for Serial Data Transmission
The receiver is built with 3-pole Phoenix connector. See below the two examples of the most common
assembling cases.
Receiver and a DCE (Data Circuit-terminating
Equipment)
Receiver and a DTE (Data Terminal Equipment)
D-SUB 9 and Phoenix
D-SUB 9 and Phoenix