background image

MANUAL

DELIVERY SET 

- Luminaire, pcs - 1
- Manual, pcs - 1
- Package, pcs - 1

FUNCTION

- overhead  luminaire  with  LED  light  source  is  designed  for  illumination  of  adjacent  territories,

open areas, road junctions, industrial areas and building's front.

- Replacement of the luminaire light source is available in the factory or in a specialized service.
- Luminaire corresponds to the safety requirements IEC 60598-2-2, EN 55015.

SAFETY NOTICE

- Never work on the luminaire when voltage is switched on.

- Do not operate the luminaire without protective grounding.

-

Position  the  luminaire  to  avoid  long  viewing  into  the  luminaire  at  a
distance of less than 0.5 m. 

- Only operate the luminaire if the diffuser is undamaged.

-

Unauthorized  disassembling,  modification  and  repair  is  prohibited.  In
case of malfunction, the luminaire should be immediately switched off
and report to manufacturer or specialized luminaire service.

-

The luminaire has passed a high voltage test for insulation and electric
strength according to IEC 60598-1.

-

The  LED  luminaries  are  considered  as  low-hazard  solid  domestic
waste  and  should  be  disposed  according  to  Directive  2002/96/EC
WEEE.

- Do not cover the luminaire with insulating material.

INSTALLATION AND OPERATION RULES 

The luminaire should be used according to «Standard code of customer electrical installations».
Installation, cleaning and replacing of the components should be done only with the main power
off. The diffuser should be cleaned with soft cloth and mild detergent.

4

Содержание 1997027060

Страница 1: ...HB LED FLOODLIGHT Manual Montageanleitung ...

Страница 2: ...nal value Luminous flux flickeing 5 Luminaire corresponds to the protection classification IP by IEC 60529 Diffuser type Polycarbonate lenses Further information about luminaire s dimensions shown in the table please see Overall and installation dimensions section Notizen Die zulässige Abweichung der Werte Leistung Lichtstrom Masse von den Sollwerten beträgt 10 Die zulässige Abweichung der CCT Wer...

Страница 3: ...Weight kg Length A mm Width B mm Heigth С mm Mounting dimension D mm Mounting dimension E mm Einschaltstro m А Einschaltstro mimpulszeit μs Gewicht kg Länge A mm Breite B mm Höhe c mm Montagemaß D mm Montagemaß E mm 65 250 37 880 535 360 320 100 3 ...

Страница 4: ... operate the luminaire if the diffuser is undamaged Unauthorized disassembling modification and repair is prohibited In case of malfunction the luminaire should be immediately switched off and report to manufacturer or specialized luminaire service The luminaire has passed a high voltage test for insulation and electric strength according to IEC 60598 1 The LED luminaries are considered as low haz...

Страница 5: ...Connect wires to free terminals L grey terminal N blue terminal PE yellow green terminal Replace cover back and tighten the screws Tightening torque 5 Nm Tighten cable gland nut until sealing is fully pressed against cable 4 For luminaries with HFD HFR Disassemble the connector Strip power cable external insulation 30 mm inner 8 mm max core section 2 5 mm2 Put cable through connector s nut and con...

Страница 6: ...Overall and installation dimensions mm 1 HB LED 400 2 HB LED 600 3 HB LED 800 CONNECTION SCHEMES 1 Mains connection scheme 2 Mains connection scheme for luminaire with 1 10V regulated control gear 6 ...

Страница 7: ...nths from date of delivery Warranty does not apply to color change of painted surfaces and plastic parts during luminaire operation Luminous flux level is at least 70 of the nominal value during the warranty period Warranty will cover the entire period given that assembly installation and operation of luminaires are handled by specialized technical personnel and according to the luminaire s manual...

Страница 8: ...Company stamp More information can be found on our website https www ltcompany com en Hotline 0049 89 550 59 8611 8 ...

Страница 9: ...n Sie die Leuchte nur in Betrieb wenn der Diffusor nicht beschädigt ist Nicht autorisiertes Zerlegen Modifizieren und Reparieren ist verboten Im Falle einer Fehlfunktion sollte die Leuchte sofort ausgeschaltet werden und sich beim Hersteller oder spezialisierten Leuchtenservice melden Leuchte hat einen Hochspannungstest für Isolation und Spannungsfestigkeit gemäß IEC 60598 1 2011 bestanden Die LED...

Страница 10: ... Aderquerschnitt 2 5 mm2 und in die Kabelverschraubung 1 einführen Die Adern an die freien Buchsen der Klemmenblöcke anschließen L grauer Block N blauer Block PE gelbgrüner Block Deckel aufsetzen Schrauben festziehen Anzugsmoment 5 Nm Ziehen Sie die Überwurfmutter an bis die Dichtung zusammengedrückt ist 4 Für Leuchten der HFD HFR Stecker zerlegen Entfernen Sie die Isolierung des Stromkabels PC au...

Страница 11: ...Gesamt und Einbaumaße der Leuchte 1 HB LED 400 2 HB LED 600 3 HB LED 800 ANSCHLUSS SCHEMA 1 ANSCHLUSS SCHEMA 2 Netzanschlussschema für Leuchten mit 1 10V geregelten Betriebsgeräten 11 ...

Страница 12: ...eckt sich über den gesamten Zeitraum da Produktion Montage und Bedienung der Leuchten von spezialisiertem Fachpersonal und gemäß Bedienungsanleitung durchgeführt werden Die Lebensdauer der Leuchte unter normalen klimatischen Bedingungen beträgt mindestens 8 Jahre insofern die Installation und Betriebsanweisungen befolgt werden 8 Jahre für Leuchten mit Gehäuse und oder optischen Teilen Diffusor aus...

Страница 13: ...Hotline Nummer 0049 89 550 59 8611 20 09 2020 2 01 14 13 ...

Отзывы: