background image

LIGHT PROGRESS 

 

 

 

 

 

 

 

 

 

    DIRECT-H-K [eng]

 

 

 

gen-2021 

 

Pag. 9/16

 

 

► UV-DIRECT-EL 

 

In model 

-EL

 you get the possibility to remote control the functionality of UV tube.  

Connected to the device there is a cable with 7 poles: a couple of poles carrying output signal to turn on LED indicating 
the  UV  lamp

(when it’s lighting); another couple of poles triggers a voltage-free contact to be activated when a  lamp-

stops  working  (alarm  function:  open  contact  if  at  least  one  lamp  UV  is  not  working);  in  addition,  there  are  two  input 
wires to power the device (phase and neutral). 
The faulty lamp alarm contact can be powered by max. 500mA of current and 24V of tension, and can be connected to 
an electronic panel as "MASTER-

ST” control unit. 

For this models see the numbering of the wires on the table below. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

In the device 

UV-DIRECT-

EL … 

Multi-pole plug 

and socket  

Wire 

Meaning 

Black

 wire for LED 

terminal n° 

1

 

Wire 

n°1

 

1-

 anode LED          for synoptic  

2-

 cathode LED         MASTER-ST...... 

Red

 wire for LED 

terminal n° 

2

 

Wire 

n°2

 

Power line 230V-50Hz - phase 

terminal n° 

3

 

Wire 

n°3

 

3-

 Line 230V-50Hz (Phase) 

Power line 230V-50Hz - Neutral 

terminal n° 

4

 

Wire 

n°4

 

4-

 Line 230V-50Hz (Neutral) 

Electrical ground  

terminal n° 

9

 

Wire 

Y/G

 

Y/G- Ground terminal 

Alarm board faulty tube 

terminal n° 

5

 

Wire 

n°5

 

5-6-

 open contact = faulty tube 

(free contact without tension, max 500 mA-24V) 

terminal n° 

6

 

Wire 

n°6

 

 

Model  

-EL

 

Содержание UV-DIRECT

Страница 1: ...LIGHT PROGRESS DIRECT H K eng gen 2021 Pag 1 16 UV DIRECT Germicidal UV C Device for Disinfection by Direct Irradiation MODELS UV DIRECT E40H K NX UV DIRECT E75H K NX...

Страница 2: ...re maintenance or cleaning ensure that the appliance is switched off and unplugged from the mains supply Should the appliance become faulty please contact our authorized Service Centre direct and in c...

Страница 3: ...it must follow the device in case of passage of property and accompany the device until its demolition To request the instruction manual updated and to ask all other information needed it s possible...

Страница 4: ...ple by means of a programming clock night op eration can be managed in the hours immediately prior to the entry of the operators to allow entry in a freshly disin fected site Operation can also be man...

Страница 5: ...ng and please be careful not to damage the con tents when using sharp blades or cutters to open the box Remove the unit from the box then inspect it immediately to ensure that no damage has occurred d...

Страница 6: ...te them uniformly in the environment to avoid the hidden areas such as the corners it should allow all the air to be treated These models can be mounted on the wall and still comply with the regular d...

Страница 7: ...the hole as shown in Figure 3C The ceiling may have a thickness from 1 mm up to 40 mm Fig 3C Fully open the locking brackets Insert the unit into the hole in the ceiling initially at one side then pas...

Страница 8: ...CTIONS We suggest you to let a qualified electrician to install this device following these instructions and the electrical scheme and following the CEI norms Make sure that the device will be install...

Страница 9: ...m contact can be powered by max 500mA of current and 24V of tension and can be connected to an electronic panel as MASTER ST control unit For this models see the numbering of the wires on the table be...

Страница 10: ...ends and pull it in a direction parallel to the tube Repeat the steps in reverse to insert the new lamp TROUBLESHOOTING UV LAMP See MAINTENANCE BALLAST All UV DIRECT models are supplied with electroni...

Страница 11: ...ainless steel AISI 304 All the used materials are tested for resistance to intense UV C rays Waterproof and dust proof IP 55 Powered with electronic ballasts specific for UV C rays lamps Reflector in...

Страница 12: ...request the return merchandise authorization RMA sending an email to in fo lightprogress it or calling the number 39 0575 749255 Once you receive the module it has to be filled up in every part and s...

Страница 13: ...hinery Guards General Requirements for the Design and construction of fixed and movable guards UNI EN ISO 13849 1 2016 Safety of Machinery Parts of the Control System related to the Safety Part 1 Gene...

Страница 14: ..._____________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ___________________...

Страница 15: ...____________________________________________ ____________________________________________________ ____________________________________________________ _________________________________________________...

Страница 16: ...g gen 2021 Pag 16 16 Loc San Lorenzo 40 52031 ANGHIARI AR ITALIA TEL 0575 74 92 55 FAX 0575 78 99 29 PRODUCTION ANGHIARI Loc San Lorenzo 40 CASTIGLION F NO Loc S Antonino 40 Http www lightprogress it...

Отзывы: