background image

LIGHT PROGRESS 

 

 

 

 

 

 

 

 

 

    DIRECT-H-K [eng]

 

 

 

gen-2021 

 

Pag. 2/16

 

 

SECURITY WARNING

 

 

  The Company has ensured that every care is taken in the design and production of its machinery. In order to guar-

antee, as far as possible, that it is safe when used correctly. However, the laws on accident prevention require all users 
of the machinery to ensure that whoever is responsible for installation, maintenance, use and sale of these products is 
shown the instruction provided by our company and is made aware of the precautions to be taken. 
According to the circumstances, the appropriate recommendations made in these instructions must be made available, 
together with any other relative information, to any company or person involved in the installation of LIGHT PRO-
GRESS products. 

  Only use this appliance for its intended purpose as described in this booklet. 

  If the appliance is wrongly operated for a purpose other than that for which it is intended, no liability can be accept-

ed for any possible damage. The manufacturer cannot be responsible for any damage to people, animals and objects 
caused by use or operation of the appliance contrary to these instructions. 

  As with all electrical appliances the safety information and precautions contained in this booklet must be carefully 

observed, including following: 

  Before maintenance or cleaning ensure that the appliance is switched off and unplugged from the mains supply. 

  Should the appliance become faulty please contact our authorized Service Centre direct and in case of repairs ask 

for genuine parts. 

Improper repairs may damage the appliance and place the user at serious risk. 

 

WARNING

 

 

 

Avoid exposition to UV-C rays emitted by germicidal lamps, 
even for few seconds, it may cause severe conjunctivitis and 
erythema 

 

Plastic or painted surfaces exposed to direct UV-C rays may 
progressively yellow, as after a long exposure to sunlight. 

 

The intended use is as a germicidal lamp for sterilization, any 
other use is improper and dangerous 

 

The lamp, as supplied, can not be modified or designed for use 
with accessories or tools 

 

We disclaim all responsibilities and void the warranty in case of 
tampering or lack of maintenance

 

 

 

Read carefully the following instruction before use  

 

In case of opening of the UV section, switch off the UV-C devices in order to avoid 
exposures to UV-C light. They may cause severe conjunctivitis and erythema. 

 

Remove the protection film from the device before switching on the UV-C lamps. 

 

This device can be used by children with no less than 8 years and by persons with 
reduced physical, sensory or metal capacities or with no experience or knowledge, as 
long as under supervision or often they have receiv3ed the related instructions about 
the safe use of the device and the related risks. Kids do not have to play with this de-
vice. 

 

Содержание UV-DIRECT

Страница 1: ...LIGHT PROGRESS DIRECT H K eng gen 2021 Pag 1 16 UV DIRECT Germicidal UV C Device for Disinfection by Direct Irradiation MODELS UV DIRECT E40H K NX UV DIRECT E75H K NX...

Страница 2: ...re maintenance or cleaning ensure that the appliance is switched off and unplugged from the mains supply Should the appliance become faulty please contact our authorized Service Centre direct and in c...

Страница 3: ...it must follow the device in case of passage of property and accompany the device until its demolition To request the instruction manual updated and to ask all other information needed it s possible...

Страница 4: ...ple by means of a programming clock night op eration can be managed in the hours immediately prior to the entry of the operators to allow entry in a freshly disin fected site Operation can also be man...

Страница 5: ...ng and please be careful not to damage the con tents when using sharp blades or cutters to open the box Remove the unit from the box then inspect it immediately to ensure that no damage has occurred d...

Страница 6: ...te them uniformly in the environment to avoid the hidden areas such as the corners it should allow all the air to be treated These models can be mounted on the wall and still comply with the regular d...

Страница 7: ...the hole as shown in Figure 3C The ceiling may have a thickness from 1 mm up to 40 mm Fig 3C Fully open the locking brackets Insert the unit into the hole in the ceiling initially at one side then pas...

Страница 8: ...CTIONS We suggest you to let a qualified electrician to install this device following these instructions and the electrical scheme and following the CEI norms Make sure that the device will be install...

Страница 9: ...m contact can be powered by max 500mA of current and 24V of tension and can be connected to an electronic panel as MASTER ST control unit For this models see the numbering of the wires on the table be...

Страница 10: ...ends and pull it in a direction parallel to the tube Repeat the steps in reverse to insert the new lamp TROUBLESHOOTING UV LAMP See MAINTENANCE BALLAST All UV DIRECT models are supplied with electroni...

Страница 11: ...ainless steel AISI 304 All the used materials are tested for resistance to intense UV C rays Waterproof and dust proof IP 55 Powered with electronic ballasts specific for UV C rays lamps Reflector in...

Страница 12: ...request the return merchandise authorization RMA sending an email to in fo lightprogress it or calling the number 39 0575 749255 Once you receive the module it has to be filled up in every part and s...

Страница 13: ...hinery Guards General Requirements for the Design and construction of fixed and movable guards UNI EN ISO 13849 1 2016 Safety of Machinery Parts of the Control System related to the Safety Part 1 Gene...

Страница 14: ..._____________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ___________________...

Страница 15: ...____________________________________________ ____________________________________________________ ____________________________________________________ _________________________________________________...

Страница 16: ...g gen 2021 Pag 16 16 Loc San Lorenzo 40 52031 ANGHIARI AR ITALIA TEL 0575 74 92 55 FAX 0575 78 99 29 PRODUCTION ANGHIARI Loc San Lorenzo 40 CASTIGLION F NO Loc S Antonino 40 Http www lightprogress it...

Отзывы: