6
(18)
1 .
DISPOSIZIONI GENERALI E GESTIONE DEL CANTIERE
1 .1 . DISPOSIZIONI GENERALI
IM.TEC.074.EN_rev.1.2
- February 2022
All rights reserved
EN
DomoFlex
- Screw-driven lifting platform
MAINTENANCE INSTRUCTIONS
2 x
MAX 50 kg
> 50 kg
IMPORTANT!
For more informa� on on safety, liability and warranty condi� ons, receipt and storage of material
on site, packaging, waste disposal, cleaning and storage of the product; refer to the "
SAFETY IN-
STRUCTIONS AND SITE MANAGEMENT
" manual.
NOTICE
PRELIMINARY CHECKS:
Once the packaging has been opened, check that the product is intact and has not been
damaged during transport. Should any anomalies or damage be found, please dispatch them in writi ng on the transport
document to the transport company, giving writt en noti ce to LIFTINGITALIA S.r.l.
CAUTION
SAFETY AND SITE MANAGEMENT - OVERALL DISPOSITIONS:
1.
Always secure tools and any objects against falling;
2.
Pay the utmost att enti on to all the steps described in this;
3.
While assembling the parts making up the system or aft er installati on, be careful of any sharp burrs (machining
residues);
•
Before proceeding with the installati on, it is necessary to remove any rubble and material deposited during the
constructi on of the shaft .
•
Only nuts and bolts included in the supply must be used.
•
The bags containing the screws must be opened in correspondence with the respecti ve operati ng phases indicated in
this manual.
•
The instructi ons described in this manual refer to a reinforced shaft , to a fastening with mechanical expansion plugs
of the stud type. For the use of plugs in masonry other than the reinforced concrete see the att achment to this
manual. For the shaft s with metal framework, we proceed by replacing the plugs with normal screws.
•
In these instructi ons and on the wiring diagram, the stops are indicated with 0, 1, (2, 3 etc.), meaning "0" the lowest stop:
the numbers on the push-butt on panels may be diff erent according to the user's needs (for example - 1, 0, etc.).
The assembly must be
performed by a MINIMUM 2
people;
If the load is greater than 50kg, use the hoist
for handling.
NOTE:
In this manual, we will talk about "SHAFT" meaning for it the base slab, the slab of landing and the ver� cal wall
that connects its slabs.
GENERAL REQUIREMENTS AND INSTALLATION SITE MANAGEMENT
GENERAL REQUIREMENTS
WARNING
RISK OF ELECTROCUTION:
The lighting and power supply systems must meet the requirements of the system and the
regulations in force. Check that it has an effective earth.
If they do not meet all the requirements,
interrupt the installation until the system has been brought up to standard
by the customer.