15
(18)
IM.TEC.074.EN_rev.1.2
- February 2022
All rights reserved
EN
DomoFlex
- Screw-driven lifting platform
MAINTENANCE INSTRUCTIONS
10 . GROUNDING
Verify the efficiency of the grounding and the electrical circuit insulation, as described in the
electrical scheme.
•
• 1
11 . LIGHTING
Check the correct functioning of the lighting systems: in the car, in the shaft (if foreseen) and
in the control cabinet.
•
• 1
12 . OVERLOAD
Make sure the operation mode with overloaded car is disabled.
A.
load the car;
B.
bring the car to the first stop;
C.
open the landing door and enter the car;
D.
close the door;
E.
make sure that the lift does not react to the inner not outer commands.
•
• 2
13 . ELECTRICAL WIRING
Check the integrity of the lines, either fixed and mobile.
•
• 2
14 . SHAFT CONTACTS
Check the integrity of the following contacts: doorlock block exclusion and floor levelling .
•
• 2
15 . PLATES - SCHEMES
Verify the presence of the followings schemes and plates:
A.
pit plate (danger in case of access, safety devices required;
B.
car roof plate (not bearing surface);
C.
control board plate (electrical hazard, access forbidden);
D.
control board plate (beside the board, emergency procedure);
E.
red emergency button identification plate;
F.
landing door plate (use reserved to less able people, for public places only);
G.
car plate (load, capacity, constructor’s name, emergency descent procedure in case of power
blackout);
H.
electrical and hydraulic schemes on the electrical panel (or machine room).
•
• 2
16 . SPEED - PICKUP - SLOWING DOWN
Make sure the actual parameters match the set values.
•
• 2
OPERATION
RECOMMENDED FREQUENCY
1st run
every
6 months
every 1/2
year(s)
every
5/10 years