background image

 

21 

 

be adjusted. Pressing “+” or “-” to adjust value. Keep pressing on “+” or “-” button, the value will  

continue to increase/decrease. When holding the pulse handlebars with both hands, PULSE LED will light up 

and display pulse  

value; if there is no pulse signal, PULSE window will display “P”.  

 

Press START/STOP button to start training.  

During training, user can adjust resistance level by pressing “+” or “-” button. When adjusting  

resistance level, RESISTANCE window will show LEVEL value for 2s then display PULSE value. 

The blue column will start blinking one by one and switch to the next one per preset time divided into 

16.  

Once the preset target data counting down to 0, the monitor will stop automatically.  

User may also press START/STOP button to stop training. Press RESET reverse to main menu. 

 

Drawing 14                                

 

 

Drawing 15                 

       

Drawing 16                                

 

 

Drawing 17 

 

 

4.2 Program mode

 

Press RESET key to go to main menu. Press “+” or “-” key and press MODE to enter PROGRAM  

mode. Entering Program mode, there are total 12 program profiles (P1~P12) (

Drawing 18~29

)  

for selection. Press “+” or “-” key button to select one profile you prefer and press MODE to  

confirm.  

 

Before exercising, user need to adjust following value: 

 

TIME:

 is blinking (

Drawing 30

). User may press “+” or “-” key to set up target training time 

from 00:00 to 99:00 (

Drawing 31

).    

DISTANCE:

 is blinking. User may press “+” or “-” button to set up target distance from 0.0~99.0.  

Press MODE to confirm setting. 

CALORIES:

 is blinking. User may press “+” or “-” button to set up target calories from 0~990,  

the increment/decrement is 10. Press MODE to confirm setting. 

PULSE:

 is blinking. User may press “+” or “-” button to set up target pulse from 0-30~230.  

Press MODE to confirm setting.  

Press START/STOP button to start training. 

Содержание ST-13

Страница 1: ...nuals are available through our website at www lifespanfitness com au Product may vary slightly from the item pictured due to model upgrades Read all instructions carefully before using this product R...

Страница 2: ...2 TABLE OF CONTENTS 1 IMPORTANT SAFETY INSTRUCTIONS 3 2 CARE INSTRUCTIONS 4 3 EXPLODED DIAGRAM 5 4 PARTS LIST 7 5 ASSEMBLY INSTRUCTIONS 12 6 COMPUTER OPERATION 17 7 EXERCISE GUIDE 28 8 WARRANTY 30...

Страница 3: ...e blood pressure or cholesterol level 3 Be aware of your body s signals Incorrect or excessive exercise can damage your health Stop exercising if you experience any of the following symptoms pain tigh...

Страница 4: ...ovement may affect the accuracy of heart rate readings The pulse sensors are intended only as exercise aids in determining heart rate trends in general 2 CARE INSTRUCTIONS a Lubricate moving joints wi...

Страница 5: ...5 3 EXPLODED DIAGRAM...

Страница 6: ...6...

Страница 7: ...Philips C K S full thread bolt M5 15 25 5 Left pedal 1 35 Philips C K S self tapping screw ST4 16 optional 30 6 Right pedal 1 36 Communication line B L 650mm 1 7 Left upper swing arm 1 37 Communicati...

Страница 8: ...hread bolt M8 20 8 25 Hex self locking nut M8 12 55 Right Pedal support 1 26 Allen cylinder head full thread bolt M8 15 12 56 Crank left 1 27 Spring washer 8 18 57 Switch 1 28 Flat washer 8 2 25 t2 0...

Страница 9: ...2 t1 5 2 80 Tube cap 38 17 5 4 114 Power line with computer tail 1 81 sliding rail tube cover 1 115 sleeve 29 26 4 0 1 82 Sliding rail aluminum sheet 4 116 sleeve 25 21 2 1 2 83 Philips C K S self tap...

Страница 10: ...8 Flat washer 8 2 25 t2 0 2 20 Curved washer 10 5 R100 t2 0 2 29 Allen Pan head half thread bolt M8 60 20 2 21 Allen pan head half thread bolt M10 70 20 6 30 Allen cylinder head full thread bolt M6 15...

Страница 11: ...11 Tool Kit List Description Specification Qty L Wrench 5 80 80S 1 L Wrench 5 35 85S 1 L Wrench 6 40 120 1 L Wrench 8 45 145 1 Phillips Wrench 14 17 75 1 Open end Wrench 15 17 1...

Страница 12: ...her 19 Allen pan head half thread screw 18 Attention Please put all the bolts and washers on the frame holes first then fix them Step 2 1 Attach the left pedal 5 to left pedal connection leg 3 with 2...

Страница 13: ...her 27 and Allen cylinder head full thread bolt 26 Then assemble the tube cover 12 on the left pedal connection leg 3 Step 4 1 Lubricate the axle of the main frame Assemble the right pedal connection...

Страница 14: ...f thread bolt 29 2 Assemble the roll wheel position stopper 13 on the right pedal connection leg 4 same as above 3 Lubricate the rail before use Step 6 1 Assemble the left upper swing arm 7 on the mai...

Страница 15: ...secure them Step 8 1 Put the hand pulse communication line 15 through the hole of main frame 1 to the console fix plate 2 Attach the handlebar group 9 to the main frame 1 fix with 4pcs flat washer 33...

Страница 16: ...pulse line 16 and hand pulse line 15 communication line B 37 and communication line B 36 2 Attach console 10 on the main frame 1 fix with 4pcs Philips C K S full thread screw 34 Step 10 1 Attach the I...

Страница 17: ...ting mode START STOP To start or stop training Stop training by pressing START STOP key the computer will remain all the setting values When power is on during workout user can press FAN button to sta...

Страница 18: ...splay power consumption during training With sensor input it will display WATT value in 3s without any signal input WATT window display 0 in 4 6s Display range 0 999 MANUAL Manually adjust workout loa...

Страница 19: ...stop power supply user can press any key or start pedaling to wake up it 4 Training mode selection After USER DATA setting then come to main menu user can press P PROGRAM or to select MANUAL PROGRAM U...

Страница 20: ...r may press or button to set up target distance from 0 0 99 0 Press MODE to confirm setting CALORIES is blinking Drawing 16 User may press or button to set up target calories from 0 990 the increment...

Страница 21: ...Press RESET reverse to main menu Drawing 14 Drawing 15 Drawing 16 Drawing 17 4 2 Program mode Press RESET key to go to main menu Press or key and press MODE to enter PROGRAM mode Entering Program mod...

Страница 22: ...g window will show LEVEL value for 2s then display PULSE value Once the preset target data counting down to 0 the monitor will stop automatically User may also press START STOP button to stop training...

Страница 23: ...mns to be set Default value 1 To finishing or quit out setting hold on MODE button for 2s Then adjust following value TIME is blinking Drawing 33 You may press UP or DOWN button to set up target train...

Страница 24: ...preset value 100 press or to adjust target pulse from 30 230 Press MODE button to enter Then adjust following value TIME is blinking You may press or button to set up target training time from 00 00...

Страница 25: ...speed is quick resistance level will be decreased Otherwise it will increase When stop training user can press RESET button to reverse to main menu Drawing 40 Drawing 41 5 RECOVERY mode If there is n...

Страница 26: ...l display as Drawing 44 46 until console finish measuring After measuring screen will display BODY FAT percentage and BMI Body Mass Index and FAT advice Drawing 47 48 Press BODY FAT button again to go...

Страница 27: ...Spec 4 short beeps function value counts down to 0 6 short beeps H R C WATT control force system to stop Other function USB charger The console can provide USB port for mobile or tablet charging MP3 p...

Страница 28: ...to success is to make exercise a regular and enjoyable part of your everyday life The condition of your heart and lungs and how efficient they are in delivering oxygen via your blood to your muscles...

Страница 29: ...for at least 1 minute Then complete 5 to 10 minutes of stretching to cool down This will increase the flexibility of your muscles and will help prevent post exercise problems Workout Guidelines TARGE...

Страница 30: ...titled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure Full details of your consumer rights may be found at www...

Страница 31: ...es Too much noise will create an incorrect reading Medical conditions or having no electrical signal in the hands are other factors that may affect pulse readings as well These are limitations of hand...

Отзывы: