20
MESSAGE
DESCRIPTION
POSSIBLE CAUSE
REMEDy
“Unexpected
interface board
reset.”
Indicates the
MIB board has
gone through an
unexpected reset.
MIB board lost
and then regained
power or was reset.
This can be caused
by electrostatic
discharge. Known
issue 07DN consoles
and 1.10 or earlier sw.
Verify connection from console’s rear plastic
to 92353 ESD Board is tight. Verify that the
lower right screw (viewed from rear) that
holds the console to the base is tight, has a
star washer, and is 8mm long.
Upgrade software to the latest release.
“Activity Zone keypad
not detected.”
The absence of a
loopback signal
indicates the Activity
Zone keypad is not
properly connected.
If it used to work,
and now doesn’t,
it is likely due to
an intermittent or
unplugged Activity
Zone connector.
If it has not worked
since the console or
MIB was replaced
(which automatically
enables the Activity
Zone detect feature),
the console - Activity
Zone cable may be
out of date.
Confirm that all connections are solid, all
wires are properly seated into the connector
and the cable is not pinched.
If the console (or MIB) has been replaced
with a newer, larger MIB (“A080-92334-0001”
on MIB silk screen), verify that the Console
Activity Zone cable is AK65-00043-0001,
rev A2 or later. replace cable if it is AK65-
00043-0000 or AK65-00043-0001, rev A1.
“Emergency stop
drive trip.”
MIB EStop drive
circuitry detects a
shorted condition.
Tether / magnet loose
or not installed;
Poly-resettable fuse
(PTC2) or Q5 on MIB
are open;
Over current
condition on
emergency stop relay
on motor controller.
Verify tether / magnet are properly replaced /
installed.
Replace MIB.
Replace Motor Controller.
"Console over
temperature.”
MIB has detected
an internal console
temperature of over
50 degrees celsius.
Console vents may
have been blocked
by a towel, etc.
This is an informational message and is
intended for engineering only.
Remove obstruction to vent.
"Network voltage
driver trip."
MIB voltage drive
circuitry to CSAFE
port detected a
shorted condition.
Faulty accessory
plugged into the
CSAFE port.
remove CSAFE accessory.
CN 17
M051-00K70-B111
Error Message Tables
Engage™ and Inspire™ Consoles
Содержание ELEVATION Series
Страница 3: ...Introduction ...
Страница 7: ...Theories of Operation ...
Страница 12: ...Problem Symptom Tables ...
Страница 15: ...Error Message Tables ...
Страница 22: ...Troubleshooting Flow Diagrams ...
Страница 35: ...How To s ...
Страница 42: ...Electrical Block Diagrams ...
Страница 43: ...43 Electrical Wiring Diagrams Engage and Inspire Consoles CN 20 Block Diagram 15 INCH CONSOLE M051 00K70 B111 ...
Страница 44: ...44 Electrical Wiring Diagrams Engage and Inspire Consoles CN 20 Block Diagram 7 Inch CONSOLE M051 00K70 B111 ...
Страница 45: ...This page intentionally left blank ...