How To’s

Engage™ and Inspire™ Consoles

M051-00K70-B111

REPLACEMENT OF OvERLAy AND BEZEL ASSEMBLy

1. 

remove the LCD console from the base unit by removing and 

saving the four screws that secure the console to the console 

support bracket. 

2. 

Disconnect the cabling from the base unit to the console. 

3. 

remove and save the six Phillips screws that secure the rear 

console case to the overlay/bezel assembly. 

4. 

remove and save the four Phillips screws (

shown in the illustration

that secure the PCB Mounting bracket assembly to the overlay/

bezel assembly. 

5. 

Tread only: disconnect green wire from the rear plastic to ESD PCB.

6. 

Inspire

TM

 Consoles only: disconnect the keypad’s tails from MIB.

7. 

Cut cable tie that secures the internal iPod

®

 cable to the plastic.

8. 

Disconnect the USB, headphones, and iPod

®

 cables from the option 

panel assembly.

9.  Install the new overlay/bezel assembly in reverse order using the 

hardware removed and saved in previous steps. 

REPLACEMENT OF 7-SEGMENT DATA DISPLAy BOARD (I-CONSOLES)

1.  Remove the rear console case. 
2. 

remove the overlay/bezel assembly. 

3. 

remove and save the four Phillips screws (

shown in the illustration

that secure the data display PCB to the PC mounting bracket. 

4. 

Disconnect any cables as required. 

5. 

re-use the spacers from the old Data Display PCB on the 

 

new Data Display PCB

6.  Install the new Data Display PCB in reverse order using the 

 

hardware removed and saved in the previous steps. 

PCB Bracket 

Mounting Screws

PCB Mounting 

Bracket Assembly

Data Display Board

Data Display 

Mounting Screws 

(4)

Содержание ELEVATION Series

Страница 1: ...95T ELEVATION SERIES TREADMILLS Service Manual M051 00K65 A003 11 16 09 ELEVATION SERIES ENGAGE TM INSPIRE TM CONSOLES Service Manual M051 00K70 B111 051210 ...

Страница 2: ...of Contents Table of Contents 2 Introduction 3 Theories of Operation 7 Problem Symptom Tables 12 Error Message Tables 15 Troubleshooting Flow Diagrams 22 How To s 35 Electrical Block Diagrams 42 M051 00K70 B111 ...

Страница 3: ...Introduction ...

Страница 4: ...ms and common causes and suggested solutions are provided Error Message Tables This section lists possible error messages that can be displayed on the consoles Descriptions possible causes and suggested remedies are provided Troubleshooting Flow Diagrams Troubleshooting Flow Diagrams are provided on several malfunctions including non responsive keypads non responsive touch screens and improper wor...

Страница 5: ... S A Tel 847 288 3300 Fax 847 288 3703 Service Email commercialservicereply lifefitness com Sales Marketing Email commercialsales lifefitness com Operating Hours 7 00 am 6 00 pm CST Latin America Caribbean Life Fitness Inc 5100 N River Road Schiller Park IL 60176 U S A Telephone 847 288 3300 Fax 847 288 3703 Service Email customersupport lifefitness com Sales Marketing Email commercialsales lifefi...

Страница 6: ...w lifefitness com for local representation or distributor dealer Belgium Life Fitness Benelux NV Parc Industrial de Petit Rechain 4800 Verviers BELGIUM Telephone 32 87 300 942 Fax 32 87 300 943 Service Email internationalservicesupport lifefitness com Sales Marketing Email marketing benelux lifefitness com Operating Hours 9 00h 17 00h CET ITALY Life Fitness Europe GmbH Siemensstraße 3 85716 Unters...

Страница 7: ...Theories of Operation ...

Страница 8: ...tainment and user interface implementations The i console features a keypad with LEDs that surrounds the LCD screen An analog TV tuner is not present in the i console The iPod Authentication Co Processor is placed on a separate board The I console has a 7 segment Data Display board to provide additional workout feedback It also interfaces to an optional attachable 17 TV The e console solely depend...

Страница 9: ... with Apple Authentication PCB 10 Interface with Life Fitness Attachable TV receive audio issue commands route iPod video to TV 11 Implement Real Time Clock with battery back up to retain Date and Time The SBC e is responsible for the following functions 1 Communication to MIB 2 Control the 15 inch LCD Backlight for LCD 3 Touch screen controller 4 Generate 3 3VDC and 5VDC for all PCBs 5 Support US...

Страница 10: ...all LEDs 13 Drive the LEDs of the Data Display and Keypad 14 Generate IR commands for Life Fitness Attachable TV Data Display Theory of Operation used on the 7 inch LCD only 1 Provides 7 segment displays to create 3 data fields of 4 3 4 numerals 2 Provides high side drive for all LEDs Analog Tuner AND APPLE AUTHENTICATION Theory of Operation USED ON THE 15 INCH LCD ONLY The functions provided by t...

Страница 11: ...hat may reach the board via Lifepulse sensor inputs This board is only used on non Tread consoles CODED RECEIVER This board receives Telemetry Heart Rate pulses from the chest strap This board implements variable gain control to ensure coded operation with the intended transmitter This board is located in the bottom portion of the Activity Zone housing on Treadmills It is located within the consol...

Страница 12: ...Problem Symptom Tables ...

Страница 13: ...eplace SBC Defective backlights Replace LCD panel Touch Screen is not accurate Touch Screen needs calibration Calibrate Touch Screen Defective LCD Touch Screen Replace the Touch Screen Touch Screen does not respond Defective LCD Touch Screen Replace the Touch Screen Gasket pressing on touch screen s active area Loosen bezel touchscreen and push gasket away from touch screen Snow and noise appear o...

Страница 14: ...00043 0001 A2 or later See service Bulletin on frame grounding Install coded receiver Emergency Stop is not working Magnet misplaced in holder MIB defective Check that the magnet is properly located in the plastic holder Replace MIB if cable and magnet good Video lockup Old revision of tuner and or SBC Try tuner revision F or later if still bad then try SBC revision E or later Distorted audio Opti...

Страница 15: ...Error Message Tables ...

Страница 16: ...software Stuck hard key detected Indicates at least one hard key on any of the keypads is being detected as closed when the MIB initially powers up Intent is to detect a faulty keypad and prevent any subsequent key events from being sent to the SBC One or more keys are either shorted closed or are being held down at power up Replace keypad s or if user is purposely holding down a key at power up t...

Страница 17: ... when prompted Maintenance shown at the top of the screen This is a data entry prompt that will ask the tech to select either Replacing Console or Replacing Motor Controller This prompt occurs if the basic configuration data stored in both the registry and motor controller doesn t match This will occur if the console or motor controller is replaced with assemblies that already have configuration d...

Страница 18: ... belt deck Check motor thermal switch connections Check clean the M C compartment insure adequate ventilation is available and it is not being heated by a heating register move from direct sunlight Replace belt deck if power level is excessive Replace motor if error keeps occurring after the motor has cooled down and no other solution has worked Warning step off belt maximum voltage trip Excessive...

Страница 19: ...m Motor disabled Non fatal error The M C has detected an open stop switch when operating that the console has not detected An intermittent console motor controller cable or emergency stop switch Confirm that all connections are solid all wires are properly seated into the connector and the cable is not pinched and being shorted open Verify proper operation of the emergency stop switch Incline inop...

Страница 20: ... connections are solid all wires are properly seated into the connector and the cable is not pinched If the console or MIB has been replaced with a newer larger MIB A080 92334 0001 on MIB silk screen verify that the Console Activity Zone cable is AK65 00043 0001 Rev A2 or later Replace cable if it is AK65 00043 0000 or AK65 00043 0001 Rev A1 Emergency stop drive trip MIB EStop drive circuitry dete...

Страница 21: ... stop switch Emergency stop tether is replaced but console still gives this message Tether magnet loose or not installed Poly resettable fuse PTC2 or Q5 on MIB are open Over current condition on emergency stop relay on motor controller Verify tether magnet are properly replaced installed Replace MIB Replace motor controller 1 When user sees this message the belt speed will decrease automatically I...

Страница 22: ...Troubleshooting Flow Diagrams ...

Страница 23: ...ce magnet Troubleshoot Base Electronics Replace Cable Replace SBC Remove cover to reveal motor control board Check main cable to MIB for power Replace MIB Change LCD panel Finished START Magnet in place Base powered up Power present on cable connector Beeps heard on power up Yes Yes Yes No No No No M051 00K70 B111 ...

Страница 24: ...pair source Finished Replace or reconnect coax jumper cable between SBC and tuner board Done reinstall analog tuner board it was probably OK Done Reinstall analog tuner and SBC They were probably OK Replace console START Video OK but no TV Signal good at Tuner Coax jumper in place if required Recheck function TV still bad Recheck function TV still bad Recheck function TV still bad No No No No No N...

Страница 25: ... cable setting is correct Verify that television signal is good at TV Replace TV See bad video Replace cable adapter or repair source START Video OK but no TV Signal good at TV No No Yes Yes M051 00K70 B111 Troubleshooting Flow Diagrams Engage and Inspire Consoles CN 24 ...

Страница 26: ...dio and iPod audio Replace LCD panel Repair no power problem Replace defective earphones Replace SBC TV only noisy replace tuner board VT iPod only noisy replace SBC Replace console Finished Install new option panel or cables or Headphone ESD PCB START START Does console have power Noise in good earphones Does keypad or touch screen function Both noisy Video working No No No No No Yes Yes Yes Yes ...

Страница 27: ... or later Verify fix grounding through frame and at console Replace cable between receiver and console Done Done Replace MIB Reposition telemetry receiver START Telemetry HR enabled in Manager s settings Correct HR shown on HR test page Correct HR shown on HR test page Correct HR Correct HR Correct HR shown on HR test page Correct HR shown on HR test page Correct HR shown on HR test page No No Yes...

Страница 28: ...IB Just Activity Zone keypad BAD Pass keypad test Yes Yes No Yes Unexpected error contact LF No Tip All hard keys keypads are connected to and processed by the MIB board Anytime a key is pressed the MIB will issue a confirmation beep unless the Club has turned Off System Sounds in Manager s Configuration Just console keypad BAD Yes No Yes Yes Yes No No Passes keypad test Passes keypad test M051 00...

Страница 29: ...nd on Place both hands on Replace cable between receiver and console Replace MIB Replace cable Finished Finished Finished Right hand on indicated Correct HR shown on HR test page Correct HR shown on test page Correct HR shown on test page No Yes Yes Yes Yes Yes No No Unexpected error contact LF No M051 00K70 B111 Troubleshooting Flow Diagrams Engage and Inspire Consoles CN 28 ...

Страница 30: ...L inverter cable or replace inverter Video good now Video good Video good No Finished Yes If possible try iPod in another machine Problem in iPod START iPod works in other machines No Change option panel and cables Change tuner board Change SBC Finished Finished Finished iPod works iPod works iPod works Yes Yes Yes Yes No No Unexpected error contact LF No Yes No M051 00K70 B111 Troubleshooting Flo...

Страница 31: ...h Calibrate Touch Screen large button Re insert USB drive and try again to calibrate touch screen Replace touch screen Unexpected error contact LF Enters calibration routine Touch screen calibration terminate successfully No No Yes Yes Finished Yes M051 00K70 B111 Troubleshooting Flow Diagrams Engage and Inspire Consoles CN 30 ...

Страница 32: ...ot Change Check touch screen calibration Replace touch screen START Calibrates successfully No Replace tuner board Replace SBC Replace MIB Finished Finished Finished Channels Change Channels Change Channels Change Yes Yes Yes Yes No No Unexpected error contact LF No M051 00K70 B111 ...

Страница 33: ... Not Change Check touch screen calibration Replace touch screen START Calibrates successfully No Replace tuner board Replace SBC Replace MIB Finished Finished Finished Audio Changes Audio Changes Audio Changes Yes Yes Yes Yes No No Unexpected error contact LF No M051 00K70 B111 ...

Страница 34: ...rt USB Drive Finished START Software update screen appears Yes Verify that USB drive is good Replace option panel Replace SBC Replace drive Finished Finished Drive good Software update screen appears Software update screen appears No Yes Yes No Yes No Unexpected error contact LF No M051 00K70 B111 ...

Страница 35: ...How To s ...

Страница 36: ...aren t any present on the new one 6 Install the new option panel assembly in reverse order using the screws removed and saved in Step 1 REPLACEMENT OF THE OPTION PANEL COMPONENTS 1 To replace the USB connector a Remove the two Phillips screws that secure the option panel to the console front b Disconnect the USB connector cable c Remove the two Phillips screws that secure the USB connector to the ...

Страница 37: ...pad s tails from MIB 7 Cut cable tie that secures the internal iPod cable to the plastic 8 Disconnect the USB headphones and iPod cables from the option panel assembly 9 Install the new overlay bezel assembly in reverse order using the hardware removed and saved in previous steps REPLACEMENT of 7 SEGMENT DATA DISPLAY BOARD i CONSOLES 1 Remove the rear console case 2 Remove the overlay bezel assemb...

Страница 38: ...priate holes in PCB Mounting Bracket then connect cables to SBC 10 Remove inverter cable and discard 11 Secure the right side of the LCD assembly to the C shaped bracket with two new M3 x 6 screws 0017 00101 1971 Secure the left side of the LCD assembly to the PCB Mounting bracket assembly with the re used screws spacers 12 Reassemble plastics in reverse order REPLACEMENT of 15 inch touch assembly...

Страница 39: ...the 15 Touch Screen Assembly to the PCB Mounting Bracket Assembly 4 Remove the four screws shown in the illustration that secure the 15 LCD to the PCB mounting bracket assembly 5 Disconnect the red black white cable AK65 00061 0000 at the LCD Route the backlight wires through the hole in the PCB mounting bracket assembly 6 Install the new 15 LCD and existing Touch Screen in reverse order using the...

Страница 40: ...ween boards 5 Install the new SBC in reverse order using the hardware removed and saved in the previous steps Reconnect all cables REPLACEMENT of machine interface board MIB 1 Remove the rear console case 2 Remove and save the four Phillips screws shown in the illustration that secure the MIB to the PC mounting bracket Disconnect the cables keypad 7 only from the MIB to the data display board 7 LC...

Страница 41: ...entication PCB 92349 5 Reinstall a console case REPLACEMENT of analog tuner 15 inch console ONly 1 Remove the rear console case 2 Remove and save the four Phillips screws shown in the illustration that secure the analog tuner to the PC mounting bracket 3 Disconnect the mini coaxial cable from the analog tuner to the SBC 4 The analog tuner is connected to the SBC via an interboard connector Careful...

Страница 42: ...Electrical Block Diagrams ...

Страница 43: ...43 Electrical Wiring Diagrams Engage and Inspire Consoles CN 20 Block Diagram 15 INCH CONSOLE M051 00K70 B111 ...

Страница 44: ...44 Electrical Wiring Diagrams Engage and Inspire Consoles CN 20 Block Diagram 7 Inch CONSOLE M051 00K70 B111 ...

Страница 45: ...This page intentionally left blank ...

Отзывы: