MESSAGE
DESCRIPTION
POSSIBLE CAUSE
REMEDy
“Notify maintenance
communication
timeout (motor
controller).”
2
Lost communications
with the motor
controller (i.e. module
communication
timeout).
Broken
communication lines,
JW3 installed on
DSP M/C.
remove JW3.
Check/replace cabling down to the M/C.
Vibration is causing intermittent operation
from loose connection.
“Notify maintenance
motor controller error
(thermal shutdown).”
Motor controller
shut down due
to excessive
temperature.
M/C compartment
airflow restricted, hot
air is being blown on
it, located in direct
sunlight.
Excessively worn
belt/deck.
Clean the M/C compartment, insure adequate
ventilation is available and it is not being
heated by a heating register, move from direct
sunlight. replace belt/deck if power level is
excessive.
“Notify maintenance
motor temperature
trip.”
Motor shut down
due to excessive
temperature.
Faulty/intermittent
thermal switch in
motor.
M/C compartment
airflow restricted, hot
air is being blown on
it, located in direct
sunlight.
Excessively worn
belt/deck.
Check motor thermal switch connections.
Check clean the M/C compartment, insure
adequate ventilation is available and it is not
being heated by a heating register, move from
direct sunlight. replace belt/deck if power
level is excessive. replace motor if error
keeps occurring after the motor has cooled
down and no other solution has worked.
“Warning - step
off belt, maximum
voltage trip.”
Excessive belt motor
bus voltage detected.
User is driving the
belt with sufficient
energy to raise the
bus voltage, most
likely at high inclines.
Input line has voltage
surge problems.
Instruct the user to not drive the belt at high
inclines or use a lower incline.
Contact an electrician to diagnose/correct a
power line problem.
“Notify maintenance
motor controller error
(hardware current
trip).”
Excessive motor
current detected.
Excessive motor
current caused
by a failed motor,
intermittent motor or
motor connection(s).
A possible but
unlikely cause would
be a severely worn
belt/deck.
Verify that all motor connections and cables
are solid. If start-up power is very weak a
phase may be faulty. Perform a phase test to
verify the system or diagnose a problem.
CN 15
M051-00K70-B111
Error Message Tables
Engage™ and Inspire™ Consoles
Содержание ELEVATION Series
Страница 3: ...Introduction ...
Страница 7: ...Theories of Operation ...
Страница 12: ...Problem Symptom Tables ...
Страница 15: ...Error Message Tables ...
Страница 22: ...Troubleshooting Flow Diagrams ...
Страница 35: ...How To s ...
Страница 42: ...Electrical Block Diagrams ...
Страница 43: ...43 Electrical Wiring Diagrams Engage and Inspire Consoles CN 20 Block Diagram 15 INCH CONSOLE M051 00K70 B111 ...
Страница 44: ...44 Electrical Wiring Diagrams Engage and Inspire Consoles CN 20 Block Diagram 7 Inch CONSOLE M051 00K70 B111 ...
Страница 45: ...This page intentionally left blank ...