Inspect the electrodes and center porcelain for deposits, and
clean with a wire brush. If the spark plug is damaged, replace
it.
Check the spark plug gap which should be 0.90
0.05mm,
and adjust by bending the side electrode if necessary.
CAUTION The spark plug must be securely tightened.
Improperly tightened plug can become very hot and possibly
damage the engine.
AIR CLEANER (EP)
(Fig. 27)
The air cleaner must be cleaned and then soaked in clean oil
at least once every 4000km’s drive. Riding in very dusty area,
the job should be done more often. See your dealer for further
information.
4. NOTES
Do not open the radiator cap just after stopping the engine. Otherwise, burn you by
aqueous vapour or boiling liquid.
Take care to discharge the coolant from the cooling system so as to prevent the crankcase
from getting liquid before maintaining the engin.
SERVICE OF COOLING SYSTEM
1. The cooling system should be checked for tightness at least once every 3000km’s
drive. Check the hoses by pressing the surfaces with finger for damage such as ageing,
cracks. If any, send it to your dealer for help.
2. Check the coolant once every 3000km’s drive as following:
(1) Check the cooland level in the radiator. The coolant may be ablated a little as the
engine runs. For adding coolant, select the same density and the same type of coolant. Do
not use water instead.
(2) Check that the coolant is clear. If it becomes cloudy or its service limit arrives, replace
it in good time.
CLEAR AWAY CARBON DEPOSIT (EP)
Clear away carbon deposit around the spark plug and piston ring, on the piston top, in
the piston ring slot and combustion chamber regularly.
SPARK PLUG (EP)
(Fig. 26)
Spark Plug Type
CPR8EA
Check and Replace
Disconnect the spark plug cap from the spark plug. Clean any dirt from around the
spark plug base. Remove the spark plug by the special wrench.
Side
electrode
Fig. 26
Seat lock
Screw
Air cleaner cover
Element
Fig. 27
Insert the ingition key into seat lock
, turn it clociwise and remove the side cover.
Drive out screw
, remove the air cleaner cover
.
Take the element
out of the housing.
Replace the element with a new one.
Reinstall all the removed parts well in the reverse order of removal.