INSTALLATION OF OUTDOOR UNIT
9
ENGLISH
Outdoor Unit PCB Setting
Procedure For Simultaneous
Operation System
1
DIP SW2 Setting
Set the DIP SW2 as below Table (
Ⓐ
)
2
Auto Addressing Method
Addressing work assigns address to each
indoor unit. When firstly installing product
or replacing the indoor unit PCB. Auto Ad-
dressing work should be done for simulta-
neous operation.
* Work procedure
- Set DIP SW2 correctly.
- Turn on main power.
- Press the SW01B for about 3 seconds
within 3 minutes After main power
on.(
Ⓑ
)
- After step 3), the LED01G(red LED) and
LED02G(green LED) rapidly flickers.
When Addressing work is done, green
LED is off, else LED (LED01G) stops flick-
ering and lights continuously. Address of
indoor unit is indicated on the wired re-
mote control display window. (CH01,
CH02, CH03, CH04)
- Press
button to turn on the indoor.
- If you fail to perform the Addressing
work, repeat step 2)~5).
* 1 means S/W on.
0 means S/W off.
Night Silent Operation setting
1
Open the side panel of outdoor unit.
2
Set the DIP SW2.
3
Close the side panel.
ON
12
3
4
5
SW
01
B
LED0
1H
DIP S
W
2
A
B
MAIN PCB
LED01G
LED02G
ON
12
3
4
5
DIP SW2
DIP SW2
Indoor Unit No.
2(Duo)
1(Single)
: Default
3(Trio)
4(Quartet)
Table DIP SW2 Setting
ON
1
2
3
4
5
0
0
0
0
0
ON
1
2
3
4
5
1
0
0
0
0
ON
1
2
3
4
5
1
1
0
0
0
ON
1
2
3
4
5
1
1
1
0
0
* 1 means S/W on.
0 means S/W off.
ON
1
2
3
4
5
0
0
0
1
0
DIP SW2
Содержание UU48WH