12
ENGLISH
Connecting the cable to Out-
door Unit
- Remove the side panel for wiring connec-
tion.
- Use the cord clamp to fix the cord.
- Earthing work
Case 1 :Terminal block of Outdoor Unit have
mark.
- Connect the cable of diameter 16mm
2
or
more to the earthing terminal provided in the
control box and do earthing.
- Case 2 :Terminal block of Outdoor Unit don't
have mark.
- Connect the cable of diameter 16mm
2
or
more, to the panel of control box, marked as
and fasten with earth screw.
Capacity 6 / 7 kW
CAUTION
• The circuit diagram is not subject to
change without notice.
• Be sure to connect wires according to
the wiring diagram.
• Connect the wires firmly, so that not to
be pulled out easily.
• Connect the wires according to color
codes by referring the wiring diagram.
!
* Make sure the rubber
bushes are Properly used
in knock-out holes after
connecting main Power
cable
Connecting
cable terminal
Power cord
terminal
Cord clamp
Cord clamp
* Make sure the rubber
bushes are
Properly used in
knock-out holes
after connecting main
power cable
Connecting
cable terminal
Power
cord
terminal
Cord
clamp
THE OUTDOOR UNIT INSTALLATION