6. Performance Data
21
THERMA V
Monobloc Type
Product Data
ZHBW126A1 [HM121MR U34] / ZHBW128A1 [HM123MR U34]
ZHBW146A1 [HM141MR U34] / ZHBW148A1 [HM143MR U34]
ZHBW166A1 [HM161MR U34] / ZHBW168A1 [HM163MR U34]
Note
1. DB : Dry bulb temperature(
℃
), LWT : Leaving water temperature(
℃
), LPM : Liter per minute (
ℓ
/min)
2. TC : Total capacity(kW), EER: Energy efficiency ratio(kW/kW), COP : Coefficient of performance (kW/kW)
3. Direct interpolation is permissible. Do not extrapolate.
4. Measuring procedure follows EN14511.
• Rated values are based on standard conditions, and it can be found on specifications.
• Above table values may not be matched according to installation condition. Except for rated value, the performance is not guaranteed.
• In accordance with the test standard(or nations), the results may vary.
5. The Shaded areas are not guaranteed continuous operation.
Outdoor
Temperature
[°C DB]
Water flow rate 34.5 LPM
LWT 7 °C
LWT 10 °C
LWT 13 °C
LWT 15 °C
LWT 18 °C
LWT 20 °C
LWT 22 °C
TC
EER
TC
EER
TC
EER
TC
EER
TC
EER
TC
EER
TC
EER
10
12.00
5.22
12.00
5.60
12.00
5.87
12.00
6.09
12.00
6.42
12.00
6.64
12.00
6.85
20
12.00
4.45
12.00
4.78
12.00
5.02
12.00
5.20
12.00
5.49
12.00
5.67
12.00
5.86
30
12.00
3.68
12.00
3.96
12.00
4.16
12.00
4.32
12.00
4.55
12.00
4.71
12.00
4.87
35
12.00
3.30
12.00
3.55
12.00
3.73
12.00
3.87
12.00
4.75
12.00
4.23
12.00
4.38
40
11.05
2.81
11.19
3.06
11.33
3.23
11.43
3.37
11.57
3.58
11.67
3.72
11.76
3.85
45
10.10
2.33
10.37
2.57
10.64
2.73
10.83
2.86
11.10
3.07
11.28
3.20
11.46
3.33
Outdoor
Temperature
[°C DB]
Water flow rate 40.3 LPM
LWT 7 °C
LWT 10 °C
LWT 13 °C
LWT 15 °C
LWT 18 °C
LWT 20 °C
LWT 22 °C
TC
EER
TC
EER
TC
EER
TC
EER
TC
EER
TC
EER
TC
EER
10
12.50
4.93
12.80
5.33
13.10
5.61
13.30
5.84
13.60
6.18
13.80
6.40
14.00
6.63
20
14.00
4.28
14.00
4.61
14.00
4.84
14.00
5.03
14.00
5.31
14.00
5.50
14.00
5.69
30
14.00
3.63
14.00
3.89
14.00
4.08
14.00
4.23
14.00
4.45
14.00
4.60
14.00
4.75
35
14.00
3.30
14.00
3.53
14.00
3.69
14.00
3.82
14.00
4.30
14.00
4.15
14.00
4.28
40
12.35
2.81
12.60
3.04
12.84
3.20
13.01
3.32
13.26
3.52
13.42
3.64
13.59
3.77
45
10.69
2.32
11.19
2.54
11.69
2.70
12.02
2.82
12.51
3.01
12.84
3.14
13.17
3.26
Outdoor
Temperature
[°C DB]
Water flow rate 46.0 LPM
LWT 7 °C
LWT 10 °C
LWT 13 °C
LWT 15 °C
LWT 18 °C
LWT 20 °C
LWT 22 °C
TC
EER
TC
EER
TC
EER
TC
EER
TC
EER
TC
EER
TC
EER
10
13.00
4.64
13.60
5.05
14.20
5.35
14.60
5.58
15.20
5.94
15.60
6.17
16.00
6.41
20
16.00
4.02
16.00
4.37
16.00
4.61
16.00
4.81
16.00
5.10
16.00
5.30
16.00
5.50
30
16.00
3.41
16.00
3.68
16.00
3.88
16.00
4.03
16.00
4.27
16.00
4.42
16.00
4.58
35
16.00
3.10
16.00
3.34
16.00
3.51
16.00
3.65
16.00
4.00
16.00
3.99
16.00
4.12
40
13.60
2.70
13.96
2.92
14.32
3.08
14.56
3.20
14.92
3.39
15.16
3.52
15.40
3.64
45
11.20
2.29
11.76
2.50
12.32
2.64
12.69
2.76
13.25
2.93
13.62
3.05
14.00
3.16
Содержание THERMAV ZHBW056A1
Страница 1: ...Air to Water Heat Pump Monobloc R32 50Hz 5BPM5 01C Replaces 5BPM5 01B P No MFL66101126 ...
Страница 2: ...THERMA V Monobloc Type General Information Product Data Design and installation ...
Страница 3: ...General Information THERMA V Monobloc Type 1 Model Line Up 2 Nomenclature ...
Страница 21: ...3 Dimensions 15 THERMA V Monobloc Type Product Data Backup Heater P No TAY37568301 ...