THERMA V
Monobloc Type
1. List of Functions
4
Product Data
■
Accessory Compatibility List
Category
Product
Remark
ZHBW056A1 [HM051MR U44]
ZHBW076A1 [HM071MR U44]
ZHBW096A1 [HM091MR U44]
ZHBW126A1 [HM121MR U34]
ZHBW146A1 [HM141MR U34]
ZHBW166A1 [HM161MR U34]
ZHBW128A1 [HM123MR U34]
ZHBW148A1 [HM143MR U34]
ZHBW168A1 [HM163MR U34]
Wired
Remote
Controller
Standard
PREMTW101
New standard (White)
O
Dry Contact
Simple Contact
PDRYCB000
Simple Dry Contact
O
Communication Type
PDRYCB400
2 Points Dry Contact (For Setback)
X
PDRYCB320
For 3rd party Thermostat
O
PDRYCB500
Dry Contact for Modbus
X
ETC
Remote temperature
sensor
PQRSTA0
-
O
Group control wire
PZCWRCG3
0.25 m
X
2-Remo Control Wire
PZCWRC2
0.25 m
O
Extension wire
PZCWRC1
10 m
O
Wi-Fi controller *
PWFMDD200
USB Cable : 0.6 m Extension cable :
0.5 m
O
Meter Interface***
PENKTH000
Interface between IDU and Meter
O
2 Zone Valve
Controller
PZNVVB200
-
X
Accessory
Kit for
AWHP
DHW tanks (Single
coil)
OSHW-200F
200 L
O
OSHW-300F
300 L
O
OSHW-500F
500 L
O
DHW tanks (Double
coil)
OSHW-300FD
300 L
O
DHW tank kit
PHLTA
For Split 1Φ
X
PHLTB
For Monobloc
O
PHLTC
For Split 3Φ
X
DHW sensor
PHRSTA0
included in DHW Tank kit
O
Thermostatic mixing
valve
OSHA-MV
3/4" DN20
O
OSHA-MV1
1" DN25
O
Backup heater
AHEH036A [HA031M E1]
220-240 V, 1Φ (For Monobloc)
O
AHEH066A [HA061M E1]
220-240 V, 1Φ (For Monobloc)
O
AHEH068A [HA063M E1]
380-415 V, 3Φ (For Monobloc)
O
AHEH066B [HA061B E1]
220-240 V, 1Φ (For Hydrosplit
HN1600MB NK0)
X
AHEH068B [HA063B E1]
380-415 V, 3Φ (For Hydrosplit
HN1600MB NK0)
X
AHEH066C [HA061C E1]
220-240 V, 1Φ (For Hydrosplit
HN1600MC NK1)
X
AHEH068C [HA063C E1]
380-415 V, 3Φ (For Hydrosplit
HN1600MC NK1)
X
3way valve
OSHA-3V
-
O
Solar thermal kit
PHLLA
-
X
2nd Circuit or
E/Heater Thermistor
PRSTAT5K10
-
O
Drain pan
PHDPB
-
X
PHDPC
-
X
Cover plate
PDC-HK10
For K1 Chassis only
X
Buffer Tank (40
ℓ
)
OSHB-40KT
For IWT(integrable)
X
DHW expansion
vessel (8
ℓ
)
OSHE-12KT
For IWT(integrable)
X
Note
1. O: Possible, X: Impossible, - : Not applicable
2. * : Some advanced functions controlled by individual controller cannot be operated.
3. ** : ACP or AC Smart is needed.
4. *** Meter interface cannot be connected at the same time with 3rd-party controller.
5. If you need more detail, please refer to the manual of product.
(http://partner.lge.com/global : Home> Doc.Library> Product > Control(BECON))
Содержание THERMAV ZHBW056A1
Страница 1: ...Air to Water Heat Pump Monobloc R32 50Hz 5BPM5 01C Replaces 5BPM5 01B P No MFL66101126 ...
Страница 2: ...THERMA V Monobloc Type General Information Product Data Design and installation ...
Страница 3: ...General Information THERMA V Monobloc Type 1 Model Line Up 2 Nomenclature ...
Страница 21: ...3 Dimensions 15 THERMA V Monobloc Type Product Data Backup Heater P No TAY37568301 ...