5-12
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Fuse blows.
Continuity.
No continuity.
Continuity.
Shorted contact at
the primary switch.
Replace fuse,
primary, monitor,
secondary
switches, and
timer switch.
No continuity.
Normal.
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Fuse blows again
Defective high volt-
age transformer.
Replace high volt-
age transformer.
Malfunction of the
monitor switch.
Replace fuse,
primary, monitor,
secondary
switches, and
timer switch.
Check continuity
of monitor
switch (with
door closed).
Check continuity
of primary
switch (with
door opened).
Disconnect one
side of the wire
lead connected
from transformer
to the high
voltage
capacitor and
operate the unit.
Replace fuse
Continuity.
Malfunction of
secondary switch.
Replace fuse,
primary, monitor,
secondary
switches, and
timer switch.
No continuity.
Check continuity
of secondary
switch (with
door opened).
2. Fuse does not
blow.
No continuity.
Continuity.
No continuity.
Defective power
supply cord.
Replace power
supply cord.
Defective
thermostat.
Replace
thermostat.
Check continuity
of thermostat.
Check continuity
of power supply
cord.
(TROUBLE 2) Oven does not operate at all, Display window does not display any figures,
and no input is accepted.
NOTE : All these switches must be replaced at the same time. Refer to page 5-8
Содержание MS-72NA
Страница 24: ...6 1 INTRODUCTION EXPLODED VIEW DOOR LATCH BOARD CONTROL PANEL INTERIOR BASE PLATE OUTER CASE EV ...
Страница 25: ...6 2 DOOR PARTS 13552A 13213A 13581A 13720D 14970A 14026A 13536A 13352A EV ...
Страница 26: ...6 3 24781T 23572A 24510L 250201 24970A 249401 26549T WTT021 CONTROL PANEL PARTS EV ...
Страница 27: ...6 4 OVEN CAVITY PARTS 33390G 35889A WTT021 33112U WTP013 36549S 33052A 948502 34960A EV ...
Страница 28: ...6 5 SUCTION GUIDE PARTS 466001 466003 WTT028 466001 43500A 56912B 55262A 43501A WSZ085 EV ...
Страница 30: ...6 7 BASE PLATE PARTS 56170D 63302A 63303A WTT021 WSZ002 948501 65006B 65006B 50CZZH WSZ002 54810C 56851D EV ...
Страница 31: ......