5-10
COMPONENTS
TEST PROCEDURE
RESULTS
RELAY 2
FAN MOTOR
(Wire leads removed)
TURNTABLE
MOTOR
(Wire leads removed)
Check for continuity of relay 2 with an
ohm-meter.
(Remove wire leads from relay 2 and
operate the unit.)
Measure the resistance.
(Ohm-meter scale: R x 1)
Measure the resistance.
(Ohm-meter scale: R x 1 )
POWER
LEVEL
1
4 sec
18 sec
2
6 sec
16 sec
3
8 sec
14 sec
4
10 sec
12 sec
5
12 sec
10 sec
6
14 sec
8 sec
7
16 sec
6 sec
8
18 sec
4 sec
9
20 sec
2 sec
10
22 sec
0 sec
Normal:
A: Approx. 85 ~ 100 ohm.
B: Approx. 10 ~ 25 ohm.
Abnormal: Infinite or several
ohms.
Normal: Approx.100~150 ohm
Abnormal: Infinite or several
ohm.
NOTE : • A MICROWAVE LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS
SERVICED FOR ANY REASON.
• MAKE SURE THE WIRE LEADS ARE IN THE CORRECT POSITION.
• WHEN REMOVING THE WIRE LEADS FROM THE PARTS, BE SURE TO GRASP THE
CONNECTOR, NOT THE WIRES.
Relay 2
A
B
Содержание MS-2642FB
Страница 26: ...6 1 EXPLODED VIEW INTRODUCTION ...
Страница 27: ...6 2 13213A 13552A 15006A 13581A 13536A 14026A 14970A 13352A 13720D DOOR PARTS ...
Страница 28: ...6 3 23506A 23572A 268711 WTP018 24781M CONTROLLER PARTS ...
Страница 29: ...6 4 36549S WTP013 33390G 34370T WTT010 WTT021 33112U 35889A WTT011 33052M OVEN CAVITY PARTS ...
Страница 30: ...6 5 WSZ085 466001 466003 466001 44510A 43500A LATCH BOARD PARTS ...
Страница 32: ...6 7 WTT021 63302A 63303A 56170D WSZ002 948503 WTT028 647781 BASE PLATE PARTS ...
Страница 33: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Страница 34: ...8 2 PRINTED CIRCUIT BOARD ...
Страница 35: ...P NO 3828W5S2284 Apr 2002 Printed in Korea ...