5-8
Component Test Procedure
CAUTIONS
1. DISCONNECT THE POWER SUPPLY CORD FROM THE OUTLET WHENEVER REMOVING THE
OUT CASE FROM THE UNIT. PROCEED WITH THE TEST ONLY AFTER DISCHARGING THE HIGH
VOLTAGE CAPACITOR AND REMOVING THE WIRE LEADS FROM THE PRIMARY WINDING OF
THE HIGH VOLTAGE TRANSFORMER. (SEE PAGE 2-1)
2. ALL OPERATIONAL CHECKS WITH MICROWAVE ENERGY MUST BE DONE WITH A LOAD (1
LITER OF WATER IN CONTAINER) IN THE OVEN.
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
TRANSFORMER
(Wire leads removed)
MAGNETRON
(Wire leads removed)
1. Measure the resistance.
(Multi-meter scale: Rx1)
●
Primary winding
●
Secondary winding
●
Filament winding
2. Measure the resistance.
(Multi-meter scale: Rx1000)
●
Primary winding to ground
●
Filament winding to ground
1. Measure the resistance.
(Multi-meter scale: Rx1)
●
Between filament terminals
2. Measure the resistance.
(Multi-meter scale: Rx1000)
●
Filament to chassis.
Approx: 1.0~2.0
Ω
Approx: 80~100
Ω
Approx: 0
Ω
Normal:
∞
Normal:
∞
Normal: Less than 1
Ω
Normal:
∞
Primary
Terminals
Secondary
Terminal
Filament
Winding
Terminal