![LG MB-308DDD Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/lg/mb-308ddd/mb-308ddd_service-manual_217178018.webp)
5-17
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Output is full when
you set lower
power level.
Abnormal.
Defective PCB
assembly.
Replace PCB
assembly.
Disconnect the
wire leads from
relay 2 and check
continuity relay 2.
(Operate the unit)
(TROUBLE 6) Oven does not cook properly when programmed for the set power level
(Operates properly on HIGH)
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Heater is not
operating.
Abnormal.
Malfunction the
heater.
Replace.
Heater.
Normal.
No continuity.
Open or loosen.
Replace or
connect tightly.
Wire connection.
(TROUBLE 7) Grill
NOTE
• MAKE SURE THE WIRE LEADS CORRECT POSITION.
• WHEN REMOVING THE WIRE LEADS FROM THE PARTS, BE SURE TO GRASP THE CONNECTOR
NOT THE WIRES.
• WHEN REMOVING THE MAGNETRON, BE SURE TO INSTALL THE MAGNETRON GASKET IN THE
CORRECT POSITION AND IN GOOD CONDITION.
2. Lower tempera-
ture in the oven.
Abnormal.
Malfunction the
heater.
Replace.
Heater.
Normal.
Abnormal.
Defective PCB
assembly.
Replace PCB
assembly.
Disconnect the
wire leads from
relay 3 and check
continuity relay 3.
(Operate the unit)