5-6
K. PCB ASSEMBLY REMOVAL
1) Remove the control panel assembly from the
cavity.
2) Remove screw which holding the PCB SUB ASM
to the control panel.
3) Disconnect the flat cable from the PCB SUB ASM
and take off the PCB SUB ASM.
L. INTERLOCK SYSTEM
1) INTERLOCK MECHANISM
The door lock mechanism is a device which has
been specially designed to completely eliminate
microwave activity when the door is opened during
cooking and thus to prevent the danger resulting
from the microwave leakage.
2) MOUNTING OF THE PRIMARY, MONITOR AND
SECONDARY SWITCH TO THE LATCH BOARD
3) INSTALLATION AND ADJUSTMENT OF THE
LATCH BOARD TO THE OVEN ASSEMBLY
●
Mount the latch board to the oven assembly.
●
Adjust the latch board in the arrow direction so
the oven door will not have any play in it when
the door is closed.
●
Tighten the mounting screw.
●
Check for playing in the door by pushing the door
release button. Door movement should be less
than 0.5mm. (1/64 inch)
Do not push the door release button while mak-
ing adjustment. Make sure that the latch moves
smoothly after adjustment are completed and
that the screws are tight.
Make sure the primary, monitor, and secondary
switch operate properly by following the continuity
test procedure.
PRIMARY
SWITCH
SECONDARY
SWITCH
MONITOR
SWITCH
ADJUSTMENT
DIRECTION