![LG MB-308DDD Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/lg/mb-308ddd/mb-308ddd_service-manual_217178015.webp)
5-14
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Fuse blows.
Continuity.
No continuity.
Continuity.
Shorted contact
the primary switch.
Replace primary
and monitor
switch.
No continuity.
Normal.
Defective high
voltage capacitor.
Replace high volt-
age capacitor.
Fuse blows again
Defective high vo-
ltage transformer.
Replace high vo-
ltage transformer.
Malfunciton of the
monitor switch.
Replace primary,
and monitor
switch.
Check continuity
of monitor
switch (with
door closed).
Check continuity
of primary
switch (with
door opened).
Disconnect one side of the wire
lead connected from transformer
to the high voltage capacitor and
operate the unit.
Replace fuse
2. Fuse does not
blow.
No continuity.
Continuity.
No continuity.
Defective power
supply cord.
Replace power
supply cord.
Defective mag-
netron thermostat.
Replace magen-
tron thermostat.
Check continuity
of magnetron
thermostat.
Check continuity
of power supply
cord.
(TROUBLE 2) Oven does not operate at all ; Display window does not display any figures
and no input is accepted.
NOTE :
•
All these switches must be replaced at the same time. Refer to page 5-6, 5-7.