Standard drawing of installation
10
Ventilator
LZ-H050GXH0 / LZ-H080GXH0 / LZ-H100GXH0
C
B
A
Model
LZ-H050GXH0
LZ-H080GXH0
LZ-H100GXH0
[Unit : mm]
Duct slope: More than 1/30(toward the wall)
Obtaining of right distance
(preventing penetration of rain water)
Ceiling Fixing Bolt
(user-supplied)
Air supply grille
Air return grille
Inspection hatch
Duct normal diameter
ØC(user-supplied)
EA
(Exaust air outlet)
OA
(Fresh air outlet)
RA
(Return air)
SA
(Supply air)
SA
(Supply air)
C
C
Water supply
shut-off valve
(user-supplied)
Drain valve
(user-supplied)
Strainer
(user-supplied)
Refrigerant piping (Liquid pipe)
(Ø 6.35 Flare connection)
Sloping downwards at a
Drain pipe
(Inner diameter : 25.4)
Feed water pipe
(
Φ
6.35 Flare connection)
Gradient of the 1/100
Cistern Tank
Refrigerant piping (Gas pipe)
(Ø12.7 Flare connection)
250
1204
1006
EA
(Exaust air outlet)
OA
(Fresh air outlet)
Ceiling suspension
bolts position
Maintenance space
Total heat Excha nger
Air Filter
Air supply grille
(user-supplied)
Air return grille
(user-supplied)
Y duct connecting
(user-supplied)
(
)
Inspection
hatch
Inspection
hatch
150~2
5
0
More than 600
150~200
600
600
600
B
A