-8-20-
TROUBLESHOOTING
Is the DLB relay normal?
Measure the resistance
Normal: infinite
Abnormal : shorted
No Replace the Relay PCB
3
Yes
Lower DLB
Relay
Upper DLB
Relay
Tab 13 and Tab 14 : RY7
Tab 24 and Tab 25: RY13
Is the value of thermistor normal?
(Refer below)
Check with the test mode To enter the test
mode, follow these steps:
(1) Press the Upper or Lower CLEAR/OFF key.
(2) Press the button in the following order : +
→
-
→
Upper
CLEAR/OFF(Upper CLEAR/OFF hold for 3 seconds)
(3) Press the START/Oven Light button again.
(4) Select the “t3” by press the + button and press the START/
Oven Light button.
Normal: Thermistor value at room temp is from 70℉ to 90℉
No
Replace the
Relay PCB
4
Current Oven
Temp
Содержание LUTG4519SN
Страница 63: ... 6 1 COMPOSITION OF CONTROL Wiring Diagram ...
Страница 66: ... 6 4 COMPOSITION OF CONTROL P N EBR80595412 Oven Relay PCB CN53 CN51 CN52 ...
Страница 67: ... 6 5 COMPOSITION OF CONTROL SMPS PCB Touch PCB P N EBR80595701 P N EBR82864102 CN02 CN01 CN1 ...
Страница 99: ...UPPER DOOR PARTS EV 1021 1009 170R 1035 1035 170L 1015 1020 173U 173U 1008 102S 102S 102L W243 1000 W222 1801 ...
Страница 100: ...LOWER DOOR PARTS EV 1041 1009 1115 1120 102L 1018 173L 102U W243 W222 W222 1100 1704 1704 102L 173L 102U W101 W101 1801 ...
Страница 105: ......