Install all appliances according to accompanying installation instructions.

5.14

Ranges equipped for installation in Canada:

Ranges equipped for use in Canada come pre-wired with a 4-wire,  

 

66 inch (168 cm) long, appliance cord and NEMA 14-50P plug.
Do not modify the factory wiring. The plug is designed to plug directly 

 

into a NEMA 14-50R electrical receptacle installed by a licensed 

electrician.

All other models:

The conduit or appliance cord installed needs to be long enough to allow 

the range to be pulled out from the wall for service, while remaining 

connected. See next page for further details.
The wiring to the range must:

Include a strain relief.

◊ 

Be terminated by tinned leads, closed loop terminals or open ended 

◊ 

spade lugs with upturned ends.

Where local code permits, a 3 or 4 wire 

appliance cord may be used. It must:

Be UL listed type SRD or SRDT.

◊ 

Be equipped with a NEMA 14-50P 4-wire 

◊ 

plug or, where local code permits, a 

NEMA 10-50P 3-wire plug.

Distinctive Range

DR30D

Optional Backguard and Island Trim Part Numbers

Description

Part Number

Island trim kit (no backguard)

ADTK30

6 inch trim kit

ADB3006

9 inch trim kit

ADB3009

Electrical Specifications

Circuit Required

Total Connected Load

240 Vac, 60 Hz., 30 Amp.*

5.7 kW (23.8 Amp.)

The ratings above are for reference only - refer to the range's product data 

label for exact specifications.

NOTE:

 This range is NOT designed for self-rimming installation or 

installation with a raised vent. 

1 1/8” (2.9 cm)

Rear of front panel/oven door

Front of knobs

Front of open door

Front panel

3” (7.6 cm)

Backguard*

6” (15.2 cm)

Backguard**

** Optional

   Standard

*

37 7/8”

(96.2 cm)

to

35 3/4”

(90.8 cm)

Width at front panel: 

29 7/8” (75.9 cm)

Finished side panel

9” (22.9 cm)

Backguard**

1 1/8” (2.9 mm) to cooking

surface (top of grates) from

top of trim

26 1/2” (67.3 cm)

28 1/2” (72.4 cm)

24 3/8” (61.9 cm)

46 3/8” (117.8 cm)

All tolerances: ±1/16” (±1.6 mm) unless otherwise stated.

 wARNINg

Observe all governing codes and ordinances during 

• 

planning and installation. Contact your local building 

department for further information. 
This appliance must be installed in accordance with 

• 

the accompanying installation instructions.

Document # PG05 - 006

Revised 1/26/10   Page 1/2

* Two 120 Vac hot (L1 and L2), one neutral, one ground

The regulator inlet accommodates a 3/4” gas line. The range ships with a 

1/2” to 3/4” adapter connected to the regulator.

gas - Electrical Access Dimensions

A

B

C

D

4 3/4”

(12.1 cm)

22 1/8”

(56.2 cm)

8 3/4”

(22.2 cm)

13 3/4”

(34.9 cm)

B

Gas 

inlet

A

C

7/8” (2.2 cm) dia. electrical 

connection hole in bottom*

D

Range electrical access, 

cover removed

GAs AND ELEctRIcAL DImENsIoNs

PRoDUct DImENsIoNs

gas Supply Pressure Requirements*

gas Type

Manifold Pressure

Minimum gas Supply 

Pressure

Natural gas

5” water column

6” water column

LP

10” water column

11” water column

* Maximum input gas supply pressure for all models is 1/2 p.s.i.

7/8" to 1 1/8" dia. access hole