10-11
Copyright ©
LG Electronics Inc. All rights reserved.
Only training and service purposes
CHECKING FLOW CHART BY FAILURE
Door lock system error
F-10 error
Normal?
Yes
Yes
Yes
END
No
Replace the micro switch
Normal?
Normal?
END
No
Replace the door locking motor
END
No
Reconnect
Replace the main PCB
Check the door locking motor (measure the resistance)
normal: approximately 3.9 kΩ
abnormal: infinite or below 5 Ω
Check the looseness of CN02
NO
COM
CN06