CHECKING FLOW CHART BY FAILURE
Sensing Fail, F1, F2?
Is the Connector
disconnected or loose?
(1) Sensor connection
(2) CN10 of Main PCB
Yes
Reconnect
or adjust the
connection
1
No
Unplug the unit
Main oven sensing error
F-1, F-2 error
CN06
Sensor connection
Yes
Go to No 4
2
No
Plug in the unit
Is the value of thermistor
normal? (Refer below)
Check with the test mode
To enter the test mode, follow these steps:
1. Press the any button, and Mode knob is
placed in the Off
2. Press the "4" and "6" key at the same time for
1 second.
3. Press the "4" and "6" key at the same time for
1 second again.
4. Press the “3” key.
Current temp
Normal : Thermistor value at room temp is from
70˚F to 90
˚
F