9-7
CHECKING FLOW CHART BY FAILURE
3
Yes
Yes
Go to No 6
4
No
Range Of resistance
Plug in the unit
Is the resistance of
thermistor normal?
Check:
Pins 4 and 5 of CN31 in main PCB
Normal
- approximately 1.09k
Ω
at 25˚C
No
Replace the
defective
Thermistor
5
Yes
Unplug the unit
CN31
6
Replace the Relay PCB.
If the same phenomenon occurs even though
after replace Relay PCB, you should replace
the Main PCB
Heater
Resistance[
Ω
]
Approximately
Broil
13.5
Conv. Heater
23
Is the value of thermistor
normal? (Refer below)
Check with the test mode
To enter the test mode, follow these steps:
1. Press the any button, and encoder is
placed in the Off
2. Press the button in the following order
: +
→
→
_
→
→
Oven light
(Oven Light hold for 3 seconds).
3. Press the OVEN LIGHT button again.
(hold for 3seconds)
4. Select the “t3” by press the + button
5. Press the START button
Normal :
Thermistor value at room temp is from
70˚F to 90
˚
F
Содержание LSE4613BD
Страница 49: ...5 3 OVEN LIGHT CR COOK TOP ELEMENT For Model LSE4613ST LSE4613BD LR RR COOK TOP ELEMENT ...
Страница 50: ...5 4 RF COOK TOP ELEMENT LF COOK TOP ELEMENT For Model LSE4613ST LSE4613BD ...
Страница 51: ...5 5 WARM PROOF EASY CLEAN BROIL ...
Страница 82: ...EXPLODED VIEW EV INTRODUCTION 9504 9501 9506 Customer Model Product Code SVC Model MODEL ...
Страница 85: ... EV COOKTOP PARTS 3056 3215 3006 3016 330M 330H 3205 3022 3204 330S 330S 301C ...
Страница 86: ...DRAWER PARTS 8523 8507 8501 8514 8517 8524 8602 8520 8512 5505 5505 8504 6008 8508 8513 1009 8708 8708 W230 EV ...
Страница 88: ......