6-12
FAILURE MODE FLOW CHART
IIs the value of thermistor
normal?
Check: using the test mode
To enter the testmode, follow these steps:
1. press the “clear” key
2. press the “BAKE”,”BROIL” key
at the same time
3. press the “BAKE”,”BROIL” key
at the same time again.
4. press the NUM “3” key
Normal :
the sensor value is from 70
˚F
to 90
˚F
at 25
˚C
.
No
Replace
the Main PCB
(EBR52349505)
4