6-9
FAILURE MODE FLOW CHART
Is the disconnect or loose
connector?
1.Sensor connection
2. CN05 of Main PCB
Yes
No
No
Power Off
Sensing Fail, F-1, F-2?
Yes
Reconnect
or repair the
connector
1
Sensor
connection
CN05
connection
Is the resistance of
thermistor normal?
Check:
Pins 1and 2 of CN5 wiring in main PCB
Normal- approximately 1.09
㏀
at 25
Ω
Yes
Replace the
failed
thermistor
2
CN5
Power Off
No
Is the value of thermistor
normal?
Check: using the test mode
To enter the testmode, follow these steps:
1. press the “clear” key
2. press the “BAKE”,”BROIL” key
at the same time
3. press the “BAKE”,”BROIL” key
at the same time again.
4. press the NUM “3” key
Normal :
the sensor value is from 70_
to 90
˚F
at 25
˚C
.
Yes
Go to No 1
3
Power On
Replace the Main PCB.
(EBR52349501)
No
Содержание LSE3092ST
Страница 55: ...5 2 Main PCB Main PCB P N EBR52349505 Power PCB Power PCB P N EBR57124701 COMPOSITION OF CONTROL ...
Страница 56: ...5 3 Relay PCB Relay PCB EBR60938302 COMPOSITION OF CONTROL Key PCB Key PCB P N EBR52350001 ...
Страница 79: ... 10 1 EXPLODED VIEW EV INTRODUCTION DOOR PARTS DRAWER PARTS COOKTOP PARTS CONTROLLER PARTS CAVITY PARTS MODEL ...
Страница 85: ......