4-4
Bake heater
Convection heater
Components
Test procedures
Results
1. Refer to page 3-11 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale : R x 1)
Normal: Approximately
17
Ω
± 10%
If not replace
1. Refer to page 3-12 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale : R x 1)
Normal: Approximately
80
Ω
± 10%
If not replace
NOTE:
Ω
Value was tested
at room temperature
(77F/25˚C)
Be careful the element is
sensitive to temperature.
NOTE:
Ω
Value was tested
at room temperature
(77F/25˚C)
Be careful the element is
sensitive to temperature.
Drawer Upper
heater
Drawer Lower
heater
1. Refer to page 3-18 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x1)
Normal : Approximately
144
Ω
± 10%
If not replace
1. Refer to page 3-18 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x1)
Normal : Approximately
72
Ω
± 10%
If not replace
NOTE:
Ω
Value was tested
at room temperature
(77F/25˚C)
Be careful the element is
sensitive to temperature.
NOTE:
Ω
Value was tested
at room temperature
(77F/25˚C)
Be careful the element is
sensitive to temperature.