- 60 -
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
• Confirm that the vertical louver is normally geared with the shaft of Stepping Motor.
• If the regular torque is detected when rotating the vertical louver with hands
⇒
Normal
• Check the connecting condition of CN-U/D Connector
• Check the soldering condition(on PCB) of CN-U/D Connector
Check the operating circuit of the vertical louver
• Confirm that there is DC +12V between pin
➀
of CN-U/D and GND.
• Confirm that there is a soldering short at following terminals.
- Between
➀
,
➁
,
➂
and
➃
of MICOM
- Between
4
,
5 , 6
and
7
of IC01M
- Between
10
,
11 , 12
and
13
of IC01M
When the horizontal louver does not operate.
Trouble 5
If there are no problems after above checks.
• Confirm the assembly condition that are catching and interfering parts in the link of the
vertical louver
Содержание LS-J0761NL
Страница 85: ...P NO 3828A20061B FEBRUARY 2008 ...