1-1 DISCONNECT POWER CORD BEFORE
SERVICING
IMPORTANT – RECONNECT ALL
GROUNDING DEVICES
All parts of this appliance capable of conducting electrical
current are grounded. If grounding wires, screws, straps,
clips, nuts or washers used to complete a path to ground
are removed for service, they must be returned to their
original position and properly fastened.
1-2 IMPORTANT NOTICE
This information is intended for use by individuals
possessing adequate backgrounds of electrical, electronic
and mechanical experience. Any attempt to repair a major
appliance may result in personal injury and property
damage. The manufacturer or seller cannot be responsible
for the interpretation of this information, nor can it assume
any liability in connection with its use.
1-3 ELECTRICAL SPECIFICATIONS
Temperature Control (Position : MID) .................... 8-(-6)°F
Defrost Control .......................................................... 7 hrs.
Defrost Thermostat ..................................................... 50°F
Electrical Rating :115V. AC, 60 Hz. ...................... 1-5 Amp.
Maximum Current Leakage ..................................... 0.5 mA
Maximum Ground Path Resistance .................. 0.14 Ohms
Energy Consumption ............... 19 cu.ft : 443 kWh/yr(Energy star)
....................................... 22 cu.ft : 468 kWh/yr(Energy star)
1-4 NO LOAD PERFORMANCE
CONTROL POSITION: MID/MID
And Ambient of : .........................70°F ..........................90°F
Fresh Food, °F ...........................33-41 ...................... 33-41
Frozen Food, °F .........................(-4)-4....................... (-4)-4
Percent Running Time ...............25-35 ...................... 45-60
1-5 REFRIGERATION SYSTEM
Minimum Compressor Capacity Vacuum ................... 21 in.
Minimum Equalized Pressure
@ 70°F ....................................................... 49 PSIG
@ 90°F ....................................................... 56 PSIG
Refrigerant - R - 134a ............................................ 5.47 oz.
Compressor ..................................................... 649 BTU/hr
1-6 INSTALLATION
Clearance must be provided at top, sides and rear of the
refrigerator for air circulation.
AT TOP ......................................................................... 1 in
AT SIDES ................................................................... 1/8 in
AT REAR ...................................................................... 1 in
1-7 REPLACEMENT PARTS
Relay ............................................................. 6748C-0004D
Overload ....................................................... 6750C-0004S
Defrost Thermostat ...................................... 6615JB2005B
Defrost Heater .............................. 19cu. ft : 5300JK1003D
............................... 22cu. ft : 5300JK1003J
Evaporator Fan Motor .................................. 4681JB1016J
Capacitor ................................................... OCZZJB2003H
Compressor (Hi-Side) .................................. 2521C-A62A8
Evaporator (Lo-Side) ..................... 19cu. ft : 5421JJ0003A
..................... 22cu. ft : 5421JJ0002A
Condenser .................................................... 5403JJ1003A
Dryer ............................................................. 5851JJ2002K
Condenser Fan Motor .................................. 4681JK1001B
Temperature Control ................................. 6871JB2043A,B
Main Control.................................................. 6871JB1185A
1-8 AIR FLOW / CIRCULATION D’AIR
- 3 -
1. SPECIFICATIONS
EVAPORATOR
COLD AIR
MIXED AIR
AIR RETURN TO
EVAPORATOR
FRESH FOOD
CONTROL
FREEZER
EVAPORATOR/
EVAPORATEUR
Содержание LRTN19320
Страница 9: ...BEST MODEL 5 CIRCUIT DIAGRAM 9 ...
Страница 10: ...BETTER MODEL 10 ...
Страница 40: ...P No 3828JL8008A MARZO 2003 Printed in México ...